Fluke Ti55FT-20 User Manual - Page 33
Table 2-3. Programmable Functions cont., Description, Laser, Start Sequence, Image Enhancement
View all Fluke Ti55FT-20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
2 Camera Overview Programming Function Buttons Table 2-3. Programmable Functions (cont.) Item Description Laser - Used to help you correlate what is on the camera display screen with what you are looking at. The laser spot is visible in the control image and can be a valuable reference point for later image review. Start Sequence - Used to quickly start the Auto Capture sequence. (Auto Capture is available on TiR2, TiR4, Ti45 and Ti55 models only.) Stop Sequence - Used to quickly stop the Auto Capture image capture sequence. (Auto Capture is available on TiR2, TiR4, Ti45 and Ti55 models only.) Image Enhancement - Used to quickly cycle through the image enhancement settings: "Off," "Normal," "Medium," and "High." Each time you press the function button, the next setting takes affect. Picture-in-Picture - Used to quickly switch between full screen view and picture-in-picture view. Recalibrate - Used to manually trigger an internal calibration adjustment. To program buttons A, B, and/or C: 1. Use the mouse controller to position the pointer over the function icon on the display screen task bar (A, B, C) you wish to program. 2. Tap E. A popup menu with list of programmable tasks appears. 3. Position the pointer over the desired task and select. 4. Repeat Steps 1-3. 2-11