Fluke Ti55FT-20 User Manual - Page 71
Resetting Image File Name Sequence Number, Selecting Video Output Options, Camera Settings, Files
View all Fluke Ti55FT-20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
6 Camera Setup Resetting Image File Name Sequence Number Resetting Image File Name Sequence Number To change the file sequence number used in the saved image name: Note If a file sequence number you want to use for image B is already used for image A, the camera automatically selects the lowest possible sequence number for image B and does not override, or delete, image A. 1. Tap F. 2. Use the mouse controller to position the pointer over Camera Settings on the popup menu. 3. Tap E. 4. Position the pointer over the Files tab and tap E. 5. Position the pointer over Reset and tap E to reset the sequence numbers back to 0000. 6. Tap to accept setting change and return to scan target mode. Selecting Video Output Options Using the video port and video cable, you can display the live, paused, or saved images on a TV, video projector, or video monitor. You can also record images on a video recorder. Video output can be set to NTSC, PAL, or disabled. Note Disable the video output function when not in use to save battery power. To select NTSC or PAL signal and enable/disable video output: 1. Plug the video cable (the end with the cylindrical noise suppressor) into the camera video port; plug the other end of the cable into the TV, projector, monitor, or video recorder. 2. Tap F on the camera. 6-9