Fluke Ti55FT-20 User Manual - Page 95
Table B-1. Troubleshooting Tips cont., Symptom, Possible Reason, Possible Solution
View all Fluke Ti55FT-20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
B Appendices Troubleshooting Table B-1. Troubleshooting Tips (cont.) Symptom Possible Reason Possible Solution Camera will not save an image. The approximate sign (~) appears in front of a temperature reading. The Compact Flash memory card is full. Insert new SanDisk-brand Compact Flash memory card, delete unnecessary images from the card (see Chapter 3), or transfer the images saved on the card to a computer hard drive and/or other back up storage device (e.g., CD-R disc). The temperature reading is outside the selected calibration range and the accuracy may not be within the specified accuracy of the camera. Change the temperature calibration range; See Setting Temperature Calibration Range, in Chapter 6. Visible light and IR images are not properly aligned. Incorrect focus, optional lenses, or 20-mm lens not properly aligned. Image alignment is disabled with 10 and 54-mm lenses. Adjust the alignment after the images are downloaded to the SmartView software. Align the 20-mm lens such that the white alignment marking on the lens lines up with the corresponding mark on the camera housing as shown in Figure 5-1. If you are unable to solve the problem using the possible solutions in the Troubleshooting table: Reboot the camera by pressing D to power off the camera, then pressing D again to power on the camera. If this still does not correct the issue: Contact Fluke as described in Chapter 1. B-3