Config Wizard The Configuration Wizard is used to configure the OmniLogic to operate the pool/spa equipment. This has already been done at installation and should not be needed unless there is a change of pool equipment. If equipment is added or taken out of the system, you may need to run the Configuration Wizard again. Instructions for the Configuration Wizard can be found in the Installation Manual. Note that if a new configuration is saved, it will overwrite the old configuration and may require you to change previous equipment settings. System Info System Info will show the Hayward Unique Address (HUA) and version for all smart components (components that communicate with the OmniLogic). This may be needed by Hayward Technical Service when troubleshooting or diagnosing system issues. Backup Config You can back up your configuration settings, schedules, setpoints etc. to the OmniLogic's internal memory or to a USB thumb drive. If using a thumb drive, use the instructions for inserting and removing thumb drives on page 26. Restore Config You can overwrite the existing configuration with a backup that is stored internally or on a thumb drive. You will get the following options when selecting Restore Config: Restore Last - this is the last backup that was saved to internal memory. Restore Prev - this is the second to last backup that was saved to internal memory. [DATE] - this is the oldest backup that was saved to internal memory. The date will be shown on the selection. Restore from USB - you can browse the USB drive and find all saved backups To restore a backup, make your selection from above and then touch Save. Display The Display Settings screen offers options to customize the way the OmniLogic displays information. firmware upgrade 1 / 2 restore config config wizard display system info wired networking backup config web server SYSTEM configuration 12h Dispensing On ºF vs% 100% DISPLAY settings 12h/24h Clock - Toggles between 12 hour and 24 hour clock. 12h ºF/ºC - Toggles between ºF and ºC. ºF vs% VSP Speed Display - Display vsp pump speed in RPM or %. Dispensing On 100% DISPLAY settings Audio - Toggles between audio on and off. Display Settings - Set display idle duration and default on settings. Display Brightness - Set display brightness. 27 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
27
Config Wizard
The Configuration Wizard is used to configure the OmniLogic to operate the pool/spa equipment.
This has already been done at installation and should not be
needed unless there is a change of pool equipment.
If equipment is added or taken out of the system, you may need to run the Configuration Wizard again.
Instructions for the Configuration Wizard can be found in the Installation Manual.
Note that if a new configuration is saved, it will overwrite the old configuration
and may require you to change previous equipment settings.
System Info
System Info will show the Hayward Unique Address (HUA) and version for all smart components (components that communicate with the OmniLogic).
This may
be needed by Hayward Technical Service when troubleshooting or diagnosing system issues.
Backup Config
You can back up your configuration settings, schedules, setpoints etc. to the OmniLogic’s internal memory or to a USB thumb drive.
If using a thumb drive, use
the instructions for inserting and removing thumb drives on page 26.
Restore Config
You can overwrite the existing configuration with a backup that is stored internally or on a thumb drive. You will get the following options when selecting Restore
Config:
Restore Last
- this is the last backup that was saved to internal memory.
Restore Prev
- this is the second to last backup that was saved to internal memory.
[DATE]
- this is the oldest backup that was saved to internal memory.
The date will be shown on the selection.
Restore from USB
- you can browse the USB drive and find all saved backups
To restore a backup, make your selection from above and then touch Save.
Display
The Display Settings screen offers options to customize the way the OmniLogic displays information.
SYSTEM
configuration
1 / 2
firmware upgrade
config wizard
system info
backup config
restore config
display
wired networking
web server
DISPLAY
settings
Dispensing On
100%
12h
F
º
vs%
DISPLAY
settings
Dispensing On
100%
12h
F
º
vs%
Display Settings
- Set display idle
duration and default on settings.
Audio
- Toggles between audio on
and off.
12h/24h Clock
- Toggles be-
tween 12 hour and 24 hour clock.
ºF/ºC
- Toggles between ºF and
ºC.
VSP Speed Display
- Display vsp
pump speed in RPM or %.
Display Brightness
- Set display
brightness.