HP 4400 HP StorageWorks Fabric OS 6.4.1 Release Notes (5697-0760, November 201 - Page 50

In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends, Fixed in Fabric OS 6.4.0

Page 50 highlights

Closed defect summary Solution Name server database counts do not match for Fabric OS 6.2.1 and M-EOS (9.9.0) switches in the same fabric, so host cannot see the device. This occurs when an HBA capable of a FDMI Register HBA (RHBA) command and M-EOS switch are in the same fabric. Fixed in Fabric OS 6.4.0 Observed termination of snmpd when SNMP queries are sent to the switch, even after deleting LogicalSwitch. Fixed in Fabric OS 6.4.0 Web Tools nameserver is not reflecting the alias and zones created in Fixed in Fabric OS 6.4.0 DCFM. When supportsave on DC SAN Backbone director is collecting the Fixed in Fabric OS 6.4.0 ASICDB data, it ties up the processor and starves other processes. Among other things, this causes CUP timeout messages on the console. Switch panic triggered by size-64 kernel message buffer being used up in virtual fabric with logical ISL configured. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Configure only DISLs between switches. DC SAN Director 6 port 10Gb FC ISL blade set to faulty 21 while traffic running through other blades in the chassis. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Run Slotpoweroff/slotpoweron the FC10-6 blade. During factory install, configdownload does not download some of Fixed in Fabric OS 6.4.0 the FCoE settings in Fabric OS 6.3.0. This issue pertains to the factory only and will not be encountered in the field. Port reference provided to FICON host by Director History Buffer incor- Fixed in Fabric OS 6.4.0 rectly references port address rather than port number. This can cause the host to reference the wrong port. Switch is not accessible through Web Tools after firmware upgrade from Fabric OS 6.2.x to Fabric OS 6.3.x. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Access switch via IP address. The switchshow command shows all PIDs the same after reboot for Fixed in Fabric OS 6.4.0 warm upgrade code path of Fabric OS 6.1 to 6.2 to 6.3. After an HCL firmware upgrade, device connectivity is lost when the Fixed in Fabric OS 6.4.0 zone is enabled on an HP StorageWorks 1606 Extension SAN Switch. Observed kernel panic when attempt to delete "base switch" in 8/40 Fixed in Fabric OS 6.4.0 switch. In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends FIP ver=0, the switch should not validate the MAC descriptor field for backwards compatibility, but it does, leading to the switch rejecting the login. Fixed in Fabric OS 6.4.0 Incorrect error message is shown in Master log after supportsave was triggered through CLI. The message we get from MAPS are not appropriate. Fixed in Fabric OS 6.4.0 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Solution
Closed defect summary
Fixed in Fabric OS 6.4.0
Name server database counts do not match for Fabric OS 6.2.1 and
M-EOS (9.9.0) switches in the same fabric, so host cannot see the
device. This occurs when an HBA capable of a FDMI Register HBA
(RHBA) command and M-EOS switch are in the same fabric.
Fixed in Fabric OS 6.4.0
Observed termination of
snmpd
when SNMP queries are sent to the
switch, even after deleting LogicalSwitch.
Fixed in Fabric OS 6.4.0
Web Tools nameserver is not reflecting the alias and zones created in
DCFM.
Fixed in Fabric OS 6.4.0
When
supportsave
on DC SAN Backbone director is collecting the
ASICDB data, it ties up the processor and starves other processes.
Among other things, this causes CUP timeout messages on the console.
Fixed in Fabric OS 6.4.0
Workaround prior to upgrade:
Configure only DISLs between
switches.
Switch panic triggered by size-64 kernel message buffer being used
up in virtual fabric with logical ISL configured.
Fixed in Fabric OS 6.4.0
Workaround prior to upgrade:
Run
Slotpoweroff
/
slotpoweron
the
FC10-6 blade.
DC SAN Director 6 port 10Gb FC ISL blade set to faulty 21 while traffic
running through other blades in the chassis.
Fixed in Fabric OS 6.4.0
During factory install,
configdownload
does not download some of
the FCoE settings in Fabric OS 6.3.0. This issue pertains to the factory
only and will not be encountered in the field.
Fixed in Fabric OS 6.4.0
Port reference provided to FICON host by Director History Buffer incor-
rectly references port address rather than port number. This can cause
the host to reference the wrong port.
Fixed in Fabric OS 6.4.0
Workaround prior to upgrade:
Access switch via IP address.
Switch is not accessible through Web Tools after firmware upgrade
from Fabric OS 6.2.x to Fabric OS 6.3.x.
Fixed in Fabric OS 6.4.0
The
switchshow
command shows all PIDs the same after reboot for
warm upgrade code path of Fabric OS 6.1 to 6.2 to 6.3.
Fixed in Fabric OS 6.4.0
After an HCL firmware upgrade, device connectivity is lost when the
zone is enabled on an HP StorageWorks 1606 Extension SAN Switch.
Fixed in Fabric OS 6.4.0
Observed kernel panic when attempt to delete "base switch" in 8/40
switch.
Fixed in Fabric OS 6.4.0
In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends
FIP ver=0
, the switch should not validate the MAC descriptor field
for backwards compatibility, but it does, leading to the switch rejecting
the login.
Fixed in Fabric OS 6.4.0
Incorrect error message is shown in Master log after
supportsave
was triggered through CLI. The message we get from MAPS are not
appropriate.
50