After firmware upgrade on DC SAN Backbone Director from Fabric OS
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Closed defect summary Solution When FCoE max login has been reached, RASLOG message was intro- Fixed in Fabric OS 6.4.0 duced to indicate FCoE login has been reached. Switch gets nsd panic when connected to a third-party switch with in- Fixed in Fabric OS 6.4.0 terop mode 3; Fabric OS 6.2 sends invalid frames. RTT counters are not displayed correctly for FCIP tunnels on idle switch Fixed in Fabric OS 6.4.0 setup. After firmware upgrade on DC SAN Backbone Director from Fabric OS 6.2.0e to 6.3.x, followed by switchdisable, policy change, and enabling some links, RTWRs were observed. This is caused by a route table getting corrupted and can lead to a host crash if on an IFL or ISL. Fixed in Fabric OS 6.4.0 Software verify error detected appears on console during upgrade to Fabric OS 6.3.0 from RC builds on HP StorageWorks 8/80 SAN Switch. This issue will not be seen in the field. Fixed in Fabric OS 6.4.0 Display of the CP disappeared from Web Tools when the blade exper- Fixed in Fabric OS 6.4.0 ienced a fault. Web Tools message Maximum length reached for your input Fixed in Fabric OS 6.4.0 in Performance Monitoring on Port Throughput and Port Error setup window. CALD panic occurred on a director and CPs got out of sync, but no failover happened as CALD was in defunct state due to race condition. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Manually reboot. Retransmit and Out of order counters displayed in the portshow fciptunnel output do not show correct values. Fixed in Fabric OS 6.4.0 400 Multiprotocol router or multiprotocol router blade non-distruptive firmware upgrade from Fabric OS 6.2.0g to 6.3.0 causes the switch to go Faulty 21. Fixed in Fabric OS 6.4.0 With 1606 Extension SAN Switch or Multiprotocol Extension Blade, Fixed in Fabric OS 6.4.0 FCIP configuration cannot be restored to default setting by using configdefault, even after chassis reboot. Circuit-0 shows InProg after changing 10G tunnel to compression enable in repeated manner during stress to fail testing. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Issuing slotpower off followed by slotpower on usually clears this problem. Interface flapping/ bad cable shows too many ras log messages Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Shut down the port and replace the faulty cable and enable the port. HP StorageWorks Fabric OS 6.4.1 Release Notes 59