HP 4400 HP StorageWorks Fabric OS 6.4.1 Release Notes (5697-0760, November 201 - Page 61
With an HP StorageWorks 1606 SAN Extension Switch and an Multi
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Closed defect summary Solution When a host in a backbone fabric with a pair of Multiprotocol Extension blades, 1606 extension SAN switches, or a combination of the two is rebooted, it is unable to discover targets in the edge fabric due to timing window where a SID zone miss could drop a frame. If initiator does not retry PLOGI, it fails to discover targets in the edge fabric. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Disable and then enable the target. NPIV tape devices may not be seen by hosts due to name server not sending subsequent PLOGI ACC following a sequence where NPIV device sends LOGO before link down. Fixed in Fabric OS 6.4.0 After upgrade to Fabric OS 6.x, rsh using user credential gets ifmodeshow eth0: ioctl (ETHTOOL_GSET) failed error in response to ifmodeshow command. Telnet and rsh with root credential work fine. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Set suid permissions for ethmode: chmod +s /fabos/libexec/ ethmode. HP StorageWorks Encryption SAN Switch or encryption blade drops frames received from the host when the back-end tape becomes unresponsive. Fixed in Fabric OS 6.4.0 When an unsupported SFP is installed in an HP StorageWorks DC SAN Director Multiprotocol Extension Blade, the amber LED flashes to indicate a fault, as it should. However, if an optical cable is plugged into the SFP, the amber LED extinguishes. The actual port status is unchanged. Fixed in Fabric OS 6.4.0 When Lossless DLS is enabled, Web Tools incorrectly shows iodset off, but the CLI shows that it is enabled. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use CLI to view the configured IOD state when IOD is enabled with Lossless DLS. In a rare circumstance with a switch running Fabric Watch, a panic can occur after fwd terminated with exit code:134, exit sig:17, and parent sig:0 when IPC buffer is overrun on a busy system. Fixed in Fabric OS 6.4.0 With an HP StorageWorks 1606 SAN Extension Switch and an Multiprotocol Extension Blade, smart data for GE-type ports (such as SFP temperature and power) are not updated in sfpshow by the automatic polling loop. Fixed in Fabric OS 6.4.0 In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends FIP ver=0, the switch should not validate the MAC descriptor field for backwards compatibility, but it does, leading to the switch rejecting the login. Fixed in Fabric OS 6.4.0 The host cannot recover if a back-end tape target becomes unresponsive Fixed in Fabric OS 6.4.0 during encryption switch-initiated commands. The supportsave command does not capture information for FIDs with index greater than 3. Fixed in Fabric OS 6.4.0 Fabric Watch sometimes logs messages with values above 100%. Most Fixed in Fabric OS 6.4.0 likely occurs during first Fabric Watch polling cycle after a slotstatsclear command is issued. Incorrect port shows I/O traffic on 2408 FCoE Switches and 10/24 Fixed in FCoE Blades. Fixed in Fabric OS 6.4.0 HP StorageWorks Fabric OS 6.4.1 Release Notes 61