HP 4400 HP StorageWorks Fabric OS 6.4.1 Release Notes (5697-0760, November 201 - Page 60
GbE ports on HP StorageWorks Extension SAN Switch or Multiprotocol
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
Closed defect summary Solution Telnet banner and switchname are not consistent after a new switchname is defined without doing multiple hafailover commands. Can also occur after a standby CP is replaced where the new CP hosts file does not get synchronized with active CP without two hafailover commands. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use the hostname xyz command when a switchname xyz is used. This issue does not occur with SSH as it does not use the banner. In a rare occurrence, HA synchronization is lost after a switch with trunk ports panics and manual reboot is needed to recover, due to race condition with trunk ports dropping Exchange Fabric Parameter (EFP) response. Fixed in Fabric OS 6.4.0 On HP StorageWorks DC SAN or DC04 Director, SwFCPortTxType Fixed in Fabric OS 6.4.0 MIB does not report the type of CoreBlade's ICL port correctly. Reports as swFCPortTxType.385 unknown(1). Byte Streaming support on 400 multiprotocol router/multiprotocol router Fixed in Fabric OS 6.4.0 blade does not work with third-party optimizers. If the ITL nexus in tape (target containers with initiator) to handle multiplex/ multistream environment is greater than 200, decreased performance is seen for some containers. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Reduce the number of IT configuration (target containers with initiators) to 200. No message is displayed when performing slotpoweroff/on on a DC SAN Backbone director. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: These messages are logged into raslog; check raslog for confirmation. The supportsave command did not remove ffdc files. Continued to Fixed in Fabric OS 6.4.0 get ffdc files warning. The file warning message persisted until a second supportsave was issued. Peak data rate is reported as 4096 MB/sec for 2 Gb/s port, which is Fixed in Fabric OS 6.4.0 not possible. In multiprotocol extension blade face plate image in Web Tools Switch Fixed in Fabric OS 6.4.0 View, 10GE ports should be renamed as XGE ports. ifName value returned for xGBE port in Web Tools does not match CLI output. Fixed in Fabric OS 6.4.0 Copper 1-GbE SFP can get into an illegal state on Extension SAN Switch Fixed in Fabric OS 6.4.0 where no LED light is shown, but port is online and working. GbE ports on HP StorageWorks Extension SAN Switch or Multiprotocol Extension Blade continually showail No_Sync status if non-B-series SFP was inserted and then replaced with B-series SFP. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use portdisable and portenable after inserting supported SFP. 60