HP 4400 HP StorageWorks Fabric OS 6.4.1 Release Notes (5697-0760, November 201 - Page 64
Web Tools Does Not Copy Effective Zone to Defined Zone DB During - will not scan
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
Closed defect summary Solution When running a third-party host scan, the http daemon (weblinker.fcg) Fixed in Fabric OS 6.4.0 terminates and restarts several times, causing a temporary management service interruption. Bad zone config message is displayed in the status message window of the zone admin module when user creates and enables a zone configuration from non-primary FCS switch. Proper error message should be given in this case. Fixed in Fabric OS 6.4.0 Virtual target edit operation (changing the LUN and enabling CHAP) causes the virtual target to disappear from the show. You may see virtual target going offline after an edit operation from Web Tools with iSCSI. Fixed in Fabric OS 6.4.0 When Replicate configuration fails due to some of the parameters, DCFM does not list them in the summary message. Fixed in Fabric OS 6.4.0 Web Tools Does Not Copy Effective Zone to Defined Zone DB During Fixed in Fabric OS 6.4.0 configupload, so Defined Zone will not be updated. Failed: Cannot start a transaction error message is dis- Fixed in Fabric OS 6.4.0 played when trying to delete the policies in open transaction. Fabric binding does not work in 239 domain mode in Interopmode 3 Fixed in Fabric OS 6.4.0 with FCR on 8Gb switches. EX_Port rejects it. 2408 FCoE switch floods FCP traffic on two ports to CNAs, and sends Fixed in Fabric OS 6.4.0 FCP traffic to the wrong CNA. Fabric OS diagnostics and POST do not illuminate any of the GEx ports during initialization, making it difficult to determine visually if there is any issue with the LEDs for these ports. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: A diagnosing command is provided to test GEx LEDs. On activating/deleting Ipfilter policy, CAL.XML error message may be Fixed in Fabric OS 6.4.0 given in Web Tools. Need to block user from manual failback to EE when switch is disabled. Fixed in Fabric OS 6.4.0 F_Port mode Top Talker monitor and EE monitor may not show the counters reliably after the fid change. Fixed in Fabric OS 6.4.0 Customer upgrades from Fabric OS 5.3.1a to 6.0.0 to 6.1.1d causes the "bufsize" value for their custom setting in fabric watch to be changed. Fixed in Fabric OS 6.4.0 The port mirroring resource not available error must be clarified Fixed in Fabric OS 6.4.0 on the CLI interface for the user. BMD core file was generated during the overnight HA reboot test on Fixed in Fabric OS 6.4.0 1606 extension SAN switch with FCIP and regular traffic. BMD crashed and core filed generated. EM computes total power usage using FRU headers instead of an internal power table. This causes multiple AP blades such as multiprotocol extension blade and 10/24 FCoE blade in a DC04 SAN director chassis to not power up when supplied with 120 VAC power. Fixed in Fabric OS 6.4.0 64