HP 4400 HP StorageWorks Fabric OS 6.4.1 Release Notes (5697-0760, November 201 - Page 72
Locked, G_Port, Disabled E_Port, Bottleneckmon, Locked G_Port, portcfg, Netbackup, slotpoweroff
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Closed defect summary Solution Webd was seen to terminate from time to time, at the same time as HA status temporarily went to non-redundant, triggering a Call Home event. Webd was killed by a watchdog as it was waiting for a reply from a busy httpd and did not have a timeout mechanism. Other than the Call Home event, no other functional impact observed. Fixed in Fabric OS 6.4.0b. Bottleneckmon cannot be enabled on F_Ports with Locked G_Port and Disabled E_Port enabled in portcfg. Fixed in Fabric OS 6.4.0b. Workaround prior to upgrade: Disable either or both Locked G_Port and Disabled E_Port features, but note that this operation is disruptive. With encryption, backup to all clear text containers using Netbackup Fixed in Fabric OS 6.4.0b. in a multiplex/stream environment causes an Encryption SAN Switch fault, resulting in tape flows hanging. DCFM encryption support is unable to import large-sized encryption certificates. When importing certificates containing both the text and Base64 encoded portion of a certificate, the import fails, but DCFM encryption support reports success. Fixed in Fabric OS 6.4.0b. Encryption FC blade in DC SAN type director can fail to properly accommodate CTC upon EG re-creation. Containers created before EG is deleted do not show up in the fabric. Fixed in Fabric OS 6.4.0b. Workaround prior to upgrade: Issue slotpoweroff/slotpoweron of encryption blade for CTCs to be hosted after EG re-creation. In large configurations, applying a new TI Zone with failover disabled Fixed in Fabric OS 6.4.0b. can cause FCIP performance to get impacted over VEX. Addition of end-to-end monitors through DCFM or CLI fails after an HA failover, if the monitors were installed on the switch before the failover on switches with Condor2 ASICs. Fixed in Fabric OS 6.4.0b. Workaround prior to upgrade: Clear all existing end-to-end monitors on the switch and try to reinstall the requested monitors. With tape pipelining enabled, AIX host gets a connection timeout error after the first write with tape pipelining enabled. Fixed in Fabric OS 6.4.0b. Workaround prior to upgrade: Disable tape pipelining. There is no way to recover device paths with FICON after CHPID cable pull without slotpoweroff/on of the Multiprotocol Extension Blade or a reboot of the 1606 Extension SAN Switch. Fixed in Fabric OS 6.4.0b. Workaround prior to upgrade: Reboot the Extension SAN Switch or Multiprotocol Extension Blade. Tape devices are intermittently detected as offline by the host during backup. Seen in setup where some physical initiators do not register as FC4 type device and others do. Unable to disable default zone from Mi10k in IM2 mode after zone merge failure between Mi10k and Fabric OS switches. Fixed in Fabric OS 6.4.0b. Fixed in Fabric OS 6.4.0b. 72