HP 4400 HP StorageWorks Fabric OS 6.4.1 Release Notes (5697-0760, November 201 - Page 67
On 4/64 SAN Switch, when HCL firmware download from Fabric OS, in AdventNet MIB Browser.
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Closed defect summary Solution The configdownload command in Fabric OS 6.2.0 config file with max tested CTCs (728) failed on 6.3.0 EG. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Do not download configuration with more than 700 containers. Unable to load IF.mib and SW.mib in AdventNet MIB Browser. Fixed in Fabric OS 6.4.0 Invalid CAL response for CAL class Brocade_SwitchFCPortStats while EnumerateSelectedInstances operation for virtual port if the virtual port has invalid CAL property, haserror property sets to 1. So SMIAgent does not return the instances for the entire logical context. Fixed in Fabric OS 6.4.0 Unable to delete ACL for a port channel in CLI. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Assign the ACL to an empty port-channel Then remove the ACL from the port-channel. Then delete the ACL. Trunking tab does not display the ICL's trunk link, whereas CLI trunk- Fixed in Fabric OS 6.4.0 show shows even if license is not installed. On certain target devices, portshow displays None on PWWN field while nsshow and switch displays PWWN on the port. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use nsshow or switch to get PWWN of the device. Encryption SAN switch - Blade processor fault when Out of Resource condition occurs and disables the ASIC. Fixed in Fabric OS 6.4.0 Transient detected error on internal link causes blade to be faulted with reason=5 or 4 on 8Gb port blades. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use slotpoweroff and slotpoweron to clear the fault. Inconsistency in encryption HACluster status, following an HA failover on a DC04 SAN director. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use portenable (ISL) or switchenable to fix the fabric. During bladeenable all blades + hafailover in a stress to fail test. One of the LISLs in a logical switch may get disabled due to zone conflict. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Issue lfcfg --lislenable to recover the disabled lisl. On 4/64 SAN Switch, when HCL firmware download from Fabric OS Fixed in Fabric OS 6.4.0 6.3 to 6.2.0g, observe termination of raslogd process. Prohibit Dynamic bit is not set in Port Descriptors when a port is prohib- Fixed in Fabric OS 6.4.0 ited only from itself. HP StorageWorks Fabric OS 6.4.1 Release Notes 67