HP 6400/8400 HP StorageWorks 6400/8400 Enterprise Virtual Array User Guide - Page 124

HBA configuration, Risks, Limitations

Page 124 highlights

• Single path HBA server can be in the same fabric as servers with multiple HBAs. • In the use of snapshots and snapclones, the source virtual disk and all associated snapshots and snapclones must be presented to the single path hosts that are zoned with the same controller. In the case of snapclones, after the cloning process has completed and the clone becomes an ordinary virtual disk, you may present that virtual disk as you would any other ordinary virtual disk. • Linux 64-bit servers can support up to14 single or dual path HBAs per server. Switch zoning and SSP are required to isolate the LUNs presented to each HBA from each other. HBA configuration • Host 1 and 2 are single path HBA hosts. • Host 3 is a dual HBA host with multi-pathing software. See Figure 38 (page 124). Risks • Single path failure may result in data loss or disk corruption. NOTE: For additional risks, see "Linux failure scenarios" (page 129). Limitations • HP P6000 Continuous Access is not supported with single path configurations. • Single path HBA server is not part of a cluster. • Booting from the SAN is supported on single path HBA servers. Figure 38 Linux (64-bit) configuration 1 Network interconnection 2 Host 3 3 Host 2 124 Single Path Implementation 6 SAN switch 1 7 SAN switch 2 8 Controller A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

Single path HBA server can be in the same fabric as servers with multiple HBAs.
In the use of snapshots and snapclones, the source virtual disk and all associated snapshots
and snapclones must be presented to the single path hosts that are zoned with the same
controller. In the case of snapclones, after the cloning process has completed and the clone
becomes an ordinary virtual disk, you may present that virtual disk as you would any other
ordinary virtual disk.
Linux 64-bit servers can support up to14 single or dual path HBAs per server. Switch zoning
and SSP are required to isolate the LUNs presented to each HBA from each other.
HBA configuration
Host 1 and 2 are single path HBA hosts.
Host 3 is a dual HBA host with multi-pathing software.
See
Figure 38 (page 124)
.
Risks
Single path failure may result in data loss or disk corruption.
NOTE:
For additional risks, see
“Linux failure scenarios” (page 129)
.
Limitations
HP P6000 Continuous Access is not supported with single path configurations.
Single path HBA server is not part of a cluster.
Booting from the SAN is supported on single path HBA servers.
Figure 38 Linux (64-bit) configuration
6 SAN switch 1
1 Network interconnection
7 SAN switch 2
2 Host 3
8 Controller A
3 Host 2
124
Single Path Implementation