HP 6400/8400 HP StorageWorks 6400/8400 Enterprise Virtual Array User Guide - Page 51
Verifying virtual disk access from the host, Configuring virtual disks from the host, HP-UX
View all HP 6400/8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
1. From HP P6000 Command View, create a virtual disk on the EVA6400/8400. 2. Specify values for the following parameters: • Virtual disk name • Vraid level • Size 3. Present the virtual disk to the host you added. 4. If applicable (OpenVMS), select a LUN number if you chose a specific LUN on the Virtual Disk Properties window. Verifying virtual disk access from the host To verify that the host can access the newly presented virtual disks, restart the host or scan the bus. If you are unable to access the virtual disk: • Verify that all cabling to the switch, EVA, and host is properly connected. • Verify all firmware levels. For more information, see the Enterprise Virtual Array QuickSpecs and associated release notes. • Ensure that you are running a supported version of the host operating system. For more information, see the HP P6000 Enterprise Virtual Array Compatibility Reference. • Ensure that the correct host is selected as the operating system for the virtual disk in HP P6000 Command View. • Ensure that the host WWN number is set correctly (to the host you selected). • Verify the FCA switch settings. • Verify that the virtual disk is presented to the host. • Verify zoning. Configuring virtual disks from the host After you create the virtual disks on the EVA6400/8400 and rescan or restart the host, follow the host-specific conventions for configuring these new disk resources. For instructions, see the documentation included with your server. HP-UX Scanning the bus To scan the FCA bus and display information about the EVA6400/8400 devices: 1. Enter the # ioscan -fnCdisk command to start the rescan. All new virtual disks become visible to the host. 2. Assign device special files to the new virtual disks using the insf command. # insf -e NOTE: Uppercase E reassigns device special files to all devices. Lowercase e assigns device special files only to the new devices-in this case, the virtual disks. The following is a sample output from an ioscan command: # ioscan -fnCdisk # ioscan -fnCdisk Class I H/W Patch Driver S/W H/W Type Description State ba 3 0/6 lba CLAIMED BUS_NEXUS Local PCI Bus Verifying virtual disk access from the host 51