HP 6400/8400 HP StorageWorks 6400/8400 Enterprise Virtual Array User Guide - Page 130
IBM AIX, VMware, Table 33 Linux failure scenarios
View all HP 6400/8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Table 33 Linux failure scenarios (continued) Fault stimulus Failure effect Controller failure Short term: I/O suspended, possible data loss. Long term: I/O halts with I/O errors, data loss. Cannot reload driver, need to reboot system, fsck should be run on any failed disks before remounting. Controller restart Short term: I/O suspended, possible data loss. Long term: I/O halts with I/O errors, data loss. Cannot reload driver, need to reboot system, fsck should be run on any failed disks before remounting. Server path failure Short: I/O suspended, possible data loss. Long: I/O halts with I/O errors, data loss. HBA driver must be reloaded before failed drives can be recovered, fsck should be run on any failed drives before remounting. Storage path failure Short: I/O suspended, possible data loss. Long: I/O halts with I/O errors, data loss. HBA driver must be reloaded before failed drives can be recovered, fsck should be run on any failed drives before remounting. IBM AIX Table 34 IBM AIX failure scenarios Fault stimulus Server failure (host power-cycled) Switch failure (SAN switch disabled) Controller failure Controller restart Server path failure Storage path failure Failure effect Check disk when rebooting. Data loss, data that finished copying survived Short term: Data transfer stops. Possible I/O errors. Long term: Repeated error messages in errpt output. System reboot causes loss of data on disk. Must crfs disk. Short term: Data transfer stops. Possible I/O errors. Long term: Repeated error messages in errpt output. System reboot causes loss of data on disk. Must crfs disk. Short term: Data transfer stops. Possible I/O errors. Long term: Repeated error messages in errpt output. System reboot causes loss of data on disk. Must crfs disk. Short term: Data transfer stops. Possible I/O errors. Long term: Repeated error messages in errpt output. System reboot causes loss of data on disk. Must crfs disk. Short term: Data transfer stops. Possible I/O errors. Long term: Repeated error messages in errpt output. System reboot causes loss of data on disk. Must crfs disk. VMware Table 35 VMware failure scenarios Fault stimulus Server failure (host power-cycled) Switch failure (SAN switch disabled) Failure effect OS reboots, automatically checks disks. HSV disks must be manually checked unless auto mounted by the system. Short: I/O suspended, possible data loss. Long: I/O halts with I/O errors, data loss. HBA driver must be reloaded before failed drives can be recovered, fsck should be run on any failed drives before remounting. 130 Single Path Implementation