HP DL360 ProLiant DL360 Generation 3 Server Maintenance and Service Guide - Page 43

Removing a DIMM from the expansion socket, in

Page 43 highlights

Removal and Replacement Procedures CAUTION: Electrostatic discharge may damage electronic components. Be sure you are properly grounded before beginning any installation procedure. Refer to "Electrostatic Discharge Information" earlier in this chapter. IMPORTANT: A memory module can be installed only one way. Be sure to match the key slots on the module with the tabs on the memory slot. Push the module down into the slot, ensuring that the module is fully inserted and properly seated. IMPORTANT: DIMMs must be installed in pairs and must be of the same size. IMPORTANT: DIMMs must be 266 MHz, PC2100 DDR SDRAM, 3.3 volts, 72-bits wide, and ECC. To remove a DIMM: 1. Power down the server. Refer to "Powering Down the Server" earlier in this chapter. 2. Remove the server from the rack. Refer to "Removing the Server from the Rack" earlier in this chapter. 3. Remove the access panel. Refer to "Server Access Panel" earlier in this chapter. 4. Open the DIMM slot latches (1). 5. Lift the DIMM from the expansion socket (2). Figure 2-36: Removing a DIMM from the expansion socket 2-32 HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Introv-ERTL Part Number: 293948-005 Last Saved On: 2/27/04 2:49 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

Removal and Replacement Procedures
CAUTION:
Electrostatic discharge may damage electronic components. Be sure you are
properly grounded before beginning any installation procedure. Refer to “Electrostatic
Discharge Information” earlier in this chapter.
IMPORTANT:
A memory module can be installed only one way. Be sure to match the key slots on the
module with the tabs on the memory slot. Push the module down into the slot, ensuring that the module
is fully inserted and properly seated.
IMPORTANT:
DIMMs must be installed in pairs and must be of the same size.
IMPORTANT:
DIMMs must be 266 MHz, PC2100 DDR SDRAM, 3.3 volts, 72-bits wide, and ECC.
To remove a DIMM:
1.
Power down the server. Refer to “Powering Down the Server” earlier in this chapter.
2.
Remove the server from the rack. Refer to “Removing the Server from the Rack” earlier
in this chapter.
3.
Remove the access panel. Refer to “Server Access Panel” earlier in this chapter.
4.
Open the DIMM slot latches (1).
5.
Lift the DIMM from the expansion socket (2).
Figure 2-36: Removing a DIMM from the expansion socket
2-32
HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide
HP CONFIDENTIAL
Codename: Introv-ERTL Part Number: 293948-005 Last Saved On: 2/27/04 2:49 PM