HP DL360 ProLiant DL360 Generation 3 Server Maintenance and Service Guide - Page 45

Processors, Processor and PPM socket locations, Table 2-3, Processor and PPM Sockets

Page 45 highlights

Removal and Replacement Procedures Processors This server can support up to two processors. Each processor has an associated processor power module (PPM) that must be present for proper operation of the server. Figure 2-38: Processor and PPM socket locations Table 2-3: Processor and PPM Sockets Item Description 1 PPM socket 1 (must always be populated) 2 Processor socket 1 (must always be populated) 3 Processor socket 2 4 PPM socket 2 Note: A PPM must be installed when a new processor is installed. WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching. CAUTION: Processor socket 1 must be populated at all times. Failure to follow this process results in the system failing to boot and halting during the Power-On Self-Test (POST). This error will result in the system not functioning properly. 2-34 HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide HP CONFIDENTIAL Codename: Introv-ERTL Part Number: 293948-005 Last Saved On: 2/27/04 2:49 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

Removal and Replacement Procedures
Processors
This server can support up to two processors. Each processor has an associated processor
power module (PPM) that must be present for proper operation of the server.
Figure 2-38: Processor and PPM socket locations
Table 2-3:
Processor and PPM Sockets
Item
Description
1
PPM socket 1 (must always be populated)
2
Processor socket 1 (must always be populated)
3
Processor socket 2
4
PPM socket 2
Note:
A PPM must be installed when a new processor is installed.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the internal
system components to cool before touching.
CAUTION:
Processor socket 1 must be populated at all times. Failure to follow this process
results in the system failing to boot and halting during the Power-On Self-Test (POST). This
error will result in the system not functioning properly.
2-34
HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide
HP CONFIDENTIAL
Codename: Introv-ERTL Part Number: 293948-005 Last Saved On: 2/27/04 2:49 PM