HP ProLiant BL660c Configuring Arrays on HP Smart Array Controllers Reference - Page 58

MSA1000 at dog sn: P56350D9IP903J, csn: 9J3CJN71XDCH, wwn

Page 58 highlights

show ssp If you use the config parameter, the output includes information about each device connected to the controller. When you use the ssp parameter, the output displays SSP information about the target controller. Example 1 => ctrl ch="lab4" show A typical output would be: MSA1000 at dog Bus Interface: Fibre WWN: 500805F3000BAC11 Serial Number: P56350D9IP903J Chassis Serial Number: 9J3CJN71XDCH Chassis Name: dog RAID 6 (ADG) Status: Enabled SSP State: Disabled Controller Status: OK Chassis Slot: 1 Hardware Revision: Rev A Firmware Version: 6.60 Rebuild Priority: Low Expand Priority: Low Surface Scan Delay: 20 sec Cache Board Present: True Cache Status: OK Accelerator Ratio: 100/0 (read/write) Read Cache Size: 128 MB Write Cache Size: 0 MB Total Cache Size: 128 MB Battery Pack Count: 1 Battery Status: OK Example 2 => ctrl all show Because this target consists of several devices, the output will be brief. A typical output would be: MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn: 500805F3000BAC11) Smart Array 5312 in Slot 3 (sn: P4AB5X9BFMLNTJ) Smart Array 532 in Slot 2 (sn: P44940LDAORS4F) Example 3 => ctrl ch="lab4" show config The output in this case will have detailed information because the target consists of only one device. A typical output would be: MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn: 500805F3000BAC11) array A (Parallel SCSI, Unused Space: 20091 MB) logicaldrive 1 (219 MB, RAID 6(ADG), OK) physicaldrive 1:3 (box 1:bay 3, Parallel SCSI, 4.3 GB, OK) physicaldrive 1:4 (box 1:bay 4, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:5 (box 1:bay 5, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:6 (box 1:bay 6, Parallel SCSI, 9.1 GB, OK) HP Array Configuration Utility 58

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

HP Array Configuration Utility
58
<target controller> show ssp
If you use the
config
parameter, the output includes information about each device connected to the
controller. When you use the
ssp
parameter, the output displays SSP information about the target
controller.
Example 1
=> ctrl ch=“lab4” show
A typical output would be:
MSA1000 at dog
Bus Interface: Fibre
WWN: 500805F3000BAC11
Serial Number: P56350D9IP903J
Chassis Serial Number: 9J3CJN71XDCH
Chassis Name: dog
RAID 6 (ADG) Status: Enabled
SSP State: Disabled
Controller Status: OK
Chassis Slot: 1
Hardware Revision: Rev A
Firmware Version: 6.60
Rebuild Priority: Low
Expand Priority: Low
Surface Scan Delay: 20 sec
Cache Board Present: True
Cache Status: OK
Accelerator Ratio: 100/0 (read/write)
Read Cache Size: 128 MB
Write Cache Size: 0 MB
Total Cache Size: 128 MB
Battery Pack Count: 1
Battery Status: OK
Example 2
=> ctrl all show
Because this target consists of several devices, the output will be brief. A typical output would be:
MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn:
500805F3000BAC11)
Smart Array 5312 in Slot 3 (sn: P4AB5X9BFMLNTJ)
Smart Array 532 in Slot 2 (sn: P44940LDAORS4F)
Example 3
=> ctrl ch="lab4" show config
The output in this case will have detailed information because the target consists of only one device. A
typical output would be:
MSA1000 at dog (sn: P56350D9IP903J, csn: (9J3CJN71XDCH, wwn:
500805F3000BAC11)
array A (Parallel SCSI, Unused Space: 20091 MB)
logicaldrive 1 (219 MB, RAID 6(ADG), OK)
physicaldrive 1:3 (box 1:bay 3, Parallel SCSI, 4.3 GB, OK)
physicaldrive 1:4 (box 1:bay 4, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:5 (box 1:bay 5, Parallel SCSI, 9.1 GB, OK)
physicaldrive 1:6 (box 1:bay 6, Parallel SCSI, 9.1 GB, OK)