HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 100
Table A-7, Description, Default Threshold, Settings, Default Alarm, Threshold, State
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
A Default Threshold Values Table A-7 provides default settings for areas in the E-Port class. Table A-7 E-Port Class Threshold Defaults Area Description Default Threshold Default Alarm Settings Settings Invalid CRC Count Monitors the number of CRC errors Unit: Error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Invalid Transmission Word Link Failure Count Monitors the number of invalid words transmitted Monitors the number of link failures Unit: Error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Unit: Error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Loss of Signal Count Loss of Synchronization Count Monitors the number of signal loss errors Monitors the number of loss of synchronization errors Unit: Error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Unit: Error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Threshold State Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range A-10 Fabric Watch Administrator's Guide Publication Number: 53-1000243-01