HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 102
Table A-8, Default Threshold, Settings, Default Alarm, Threshold, State
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
A Default Threshold Values Table A-8 provides default settings for areas in the F/FL_Port class. Table A-8 F/FL_Port Class Threshold Defaults Area Description Default Threshold Default Alarm Settings Settings Loss of Synchronization Count Monitors the number of loss of synchronization errors Unit: Error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Receive Performance State Changes Monitors the receive rate, by percentage Monitors state changes Unit: Percentage(%) Time Base: minute Low: 0 High: 100 Buffer: 0 Unit: Change(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Transmit Performance Monitors the transmit rate, by percentage Invalid CRC Count Monitors the number of CRC errors Unit: Percentage(%) Time Base: minute Low: 0 High: 100 Buffer: 0 Unit: Error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Threshold State Informative Informative Out_of_range In_range Informative Informative Informative Informative Informative Informative Informative Out_of_range In_range Informative Informative Informative Informative Informative Informative Informative Out_of_range In_range A-12 Fabric Watch Administrator's Guide Publication Number: 53-1000243-01