HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 95
Fabric Class, Default Threshold Values, Fabric Class Threshold Defaults
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Default Threshold Values A Fabric Class Table A-2 provides default settings for areas in the Fabric class. These defaults are hardware-dependent. Check the appropriate Hardware Reference Manual for differences in environmental requirements. Table A-2 Fabric Class Threshold Defaults Area Description Default Threshold Default Alarm Threshold Settings Settings State Domain ID Changes Monitors forcible DOMAIN ID changes Unit: D_ID Change(s) Changed: 0 Time Base: none Below: 0 Low: 0 Above: 0 High: 0 In-Between: 0 Buffer: 0 Informative Informative Informative Informative SFP State Changes Monitors the insertion and removal of SFPs Unit: Change(s) Time Base: none Low: 0 High: 0 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Informative Informative Loss of E_Port Monitors E_Port and VE_Port status Unit: Down(s) Time Base: none Low: 0 High: 0 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Informative Informative Fabric Logins Monitors host device fabric logins Unit: Login(s) Time Base: none Low: 0 High: 0 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Informative Informative Fabric Watch Administrator's Guide A-5 Publication Number: 53-1000243-01