HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 107

SFP Class, Default Threshold Values, SFP Class Threshold Defaults

Page 107 highlights

Default Threshold Values A SFP Class Table A-11 provides default settings for areas in the SFP class. Note SFPs connected to GbE ports are not monitored. Table A-11 SFP Class Threshold Defaults Area Description Default Threshold Settings Current Monitors SFP current Receive Power Monitors receive power in µWatts Supply Voltage Monitors SFP electrical force in volt(s) Unit: mA Time Base: none Low: 0 High: 50 Buffer: 1 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Unit: mV Time Base: none Low: 3150 High: 3600 Buffer: 10 Temperature Transmit Power Monitors SFP Temperature Monitors transmit power in µWatts Unit: Degrees C Time Base: none Low: -10 High: 85 Buffer: 3 Unit: µWatts Time Base: none Low: 0 High: 5000 Buffer: 25 Default Alarm Settings Changed: 0 Below: 1 Above: 1 In-Between: 0 Threshold State Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Informative Changed: 0 Below: 1 Above: 1 In-Between: 1 Informative Out_of_range Out_of_range Normal Changed: 0 Below: 1 Above: 1 In-Between: 0 Informative Out_of_range Out_of_range Normal Fabric Watch Administrator's Guide Publication Number: 53-1000243-01 A-17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

Fabric Watch Administrator’s Guide
A-17
Publication Number: 53-1000243-01
Default Threshold Values
A
SFP Class
Table A-11
provides default settings for areas in the SFP class.
Note
SFPs connected to GbE ports are not monitored.
Table A-11
SFP Class Threshold Defaults
Area
Description
Default Threshold
Settings
Default Alarm
Settings
Threshold
State
Current
Monitors SFP
current
Unit: mA
Time Base: none
Low: 0
High: 50
Buffer: 1
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Receive Power
Monitors receive
power in μWatts
Unit: μWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Supply Voltage
Monitors SFP
electrical force in
volt(s)
Unit: mV
Time Base: none
Low: 3150
High: 3600
Buffer: 10
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Informative
Temperature
Monitors SFP
Temperature
Unit: Degrees C
Time Base: none
Low: -10
High: 85
Buffer: 3
Changed: 0
Below: 1
Above: 1
In-Between: 1
Informative
Out_of_range
Out_of_range
Normal
Transmit
Power
Monitors transmit
power in μWatts
Unit: μWatts
Time Base: none
Low: 0
High: 5000
Buffer: 25
Changed: 0
Below: 1
Above: 1
In-Between: 0
Informative
Out_of_range
Out_of_range
Normal