HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 92

Environment Class, Default Threshold Values, Environment Class Threshold Defaults

Page 92 highlights

A Default Threshold Values Environment Class Table A-1 provides default settings for areas in the Environment class. These defaults are hardwaredependent. Check the appropriate hardware reference manual for differences in environmental requirements. Note For the SilkWorm 200E, there is no fan default threshold because the fans are not monitored by Fabric Watch. You can use the fanShow command to view the SilkWorm 200E fan status (OK or NOT OK). However, you cannot use the fwConfigure command to manipulate the threshold or alarm actions against any fans. Table A-1 Area Fan Environment Class Threshold Defaults Description Default Threshold Settings Monitors switch fan Unit: RPM speed in RPMs Time Base: none SilkWorm 3850 and 3250 Low: 4500 High: 11000 Buffer: 3 SilkWorm 3900 Low: 2600 High: 10000 Buffer: 3 SilkWorm 4100 Low: 3000 High: 12000 Buffer: 3 SilkWorm 4900 Low: 4100 High: 8500 Buffer: 3 SilkWorm 7500 Low: 5000 High: 16000 Buffer: 3 SilkWorm 24000 Low: 1600 High: 3400 Buffer: 3 SilkWorm 48000 Low: 1600 High: 3400 Buffer: 3 Default Alarm Settings Changed: 0 Above: 3 Below: 3 In-Between: 1 Threshold State Informative Out_of_range Out_of_range In_range A-2 Fabric Watch Administrator's Guide Publication Number: 53-1000243-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

A-2
Fabric Watch Administrator’s Guide
Publication Number: 53-1000243-01
Default Threshold Values
A
Environment Class
Table A-1
provides default settings for areas in the Environment class. These defaults are hardware-
dependent. Check the appropriate hardware reference manual for differences in environmental
requirements.
Note
For the SilkWorm 200E, there is no fan default threshold because the fans are not monitored by Fabric
Watch. You can use the
fanShow
command to view the SilkWorm 200E fan status (OK or NOT OK).
However, you cannot use the
fwConfigure
command
to manipulate the threshold or alarm actions
against any fans.
Table A-1
Environment Class Threshold Defaults
Area
Description
Default Threshold
Settings
Default Alarm
Settings
Threshold
State
Fan
Monitors switch fan
speed in RPMs
Unit: RPM
Time Base: none
SilkWorm 3850 and
3250
Low: 4500
High: 11000
Buffer: 3
SilkWorm 3900
Low: 2600
High: 10000
Buffer: 3
SilkWorm 4100
Low: 3000
High: 12000
Buffer: 3
SilkWorm 4900
Low: 4100
High: 8500
Buffer: 3
SilkWorm 7500
Low: 5000
High: 16000
Buffer: 3
SilkWorm 24000
Low: 1600
High: 3400
Buffer: 3
SilkWorm 48000
Low: 1600
High: 3400
Buffer: 3
Changed: 0
Above: 3
Below: 3
In-Between: 1
Informative
Out_of_range
Out_of_range
In_range