HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 78

Configuring Fabric Watch Using SNMP, Example swFwName Screen,

Page 78 highlights

3 Configuring Fabric Watch Using SNMP For detailed descriptions of the SNMP fields in both telnet and Web Tools, see the Fabric OS MIB Reference. Figure 3-8 Example swFwName Screen In this example, 83.1 is numeric identifier for the element referenced as resFlash000. 8. Traverse the fields beneath swFwClassAreaTable and swFwThresholdTable, appending the numeric identifier from the previous step to each field before performing a get or write operation. For example, to get and modify information specific to the resFlash000 element, select one of the fields and append "83.1" in the Object ID field on the right side of the screen. To modify information, you must define a write community. To modify an entry: a. Select a field. b. Append the numeric identifier to the Object ID. c. Enter the new value into the Set Value field. d. Select Set from the Operations menu. 3-30 Fabric Watch Administrator's Guide Publication Number: 53-1000243-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

3-30
Fabric Watch Administrator’s Guide
Publication Number: 53-1000243-01
Configuring Fabric Watch Using SNMP
3
For detailed descriptions of the SNMP fields in both telnet and Web Tools, see the
Fabric OS MIB
Reference.
Figure 3-8
Example swFwName Screen
In this example, 83.1 is numeric identifier for the element referenced as resFlash000.
8.
Traverse the fields beneath swFwClassAreaTable and swFwThresholdTable, appending the numeric
identifier from the previous step to each field before performing a get or write operation. For
example, to get and modify information specific to the resFlash000 element, select one of the fields
and append “83.1” in the Object ID field on the right side of the screen.
To modify information, you must define a write community. To modify an entry:
a.
Select a field.
b.
Append the numeric identifier to the Object ID.
c.
Enter the new value into the Set Value field.
d.
Select
Set
from the Operations menu.