HP StorageWorks 2/16V Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 55

Configuring Fabric Watch Thresholds, Advanced Configuration Menu

Page 55 highlights

Configuring Fabric Watch Thresholds 3 See Chapter 1, "Fabric Watch Concepts" for more details about threshold and buffer values. 1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] 4 Index ThresholdName 216 eportRXPerf216 217 eportRXPerf217 218 eportRXPerf218 219 eportRXPerf219 220 eportRXPerf220 221 eportRXPerf221 222 eportRXPerf222 223 eportRXPerf223 BehaviorType Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 BehaviorInt Threshold boundary level is setat : Default DefaultCustom Unit Percentage(%) Time base minuteminute Low 0 0 High 100 100 BufSize 0 0 Percentage(%) Threshold alarmlevel is set at: Default Errlog-1, SnmpTrap-2, PortLogLock-4 RapiTrap-8, EmailAlert-16 Valid alarm matrix is 31 DefaultCustom Changed 0 0 Below 0 0 Above 0 0 InBetween 0 0 1 : change behavior type 11 : change threshold alarm level 2 : change behavior interval 12 : change changed alarm 3 : change threshold boundary level 13 : change belowalarm 4 : change custom unit 14 : change abovealarm 5 : change custom timebase 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18]7 Figure 3-1 Advanced Configuration Menu Note To ensure that your threshold setting configuration takes effect, remember to change the threshold boundary level to Custom using option 3, and then apply the threshold boundary level settings using option 16. Fabric Watch Administrator's Guide 3-7 Publication Number: 53-1000243-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

Fabric Watch Administrator’s Guide
3-7
Publication Number: 53-1000243-01
Configuring Fabric Watch Thresholds
3
See
Chapter 1, “Fabric Watch Concepts”
for more details about threshold and buffer values.
Figure 3-1
Advanced Configuration Menu
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select choice => : (1..5) [5]
4
Index ThresholdName
BehaviorType
BehaviorInt
216 eportRXPerf216
Triggered
1
217 eportRXPerf217
Triggered
1
218 eportRXPerf218
Triggered
1
219 eportRXPerf219
Triggered
1
220 eportRXPerf220
Triggered
1
221 eportRXPerf221
Triggered
1
222 eportRXPerf222
Triggered
1
223 eportRXPerf223
Triggered
1
Threshold boundary level is setat : Default
DefaultCustom
Unit
Percentage(%)
Percentage(%)
Time base
minuteminute
Low
0
0
High
100
100
BufSize
0
0
Threshold alarmlevel is set at: Default
Errlog-1, SnmpTrap-2, PortLogLock-4
RapiTrap-8, EmailAlert-16
Valid alarm matrix is 31
DefaultCustom
Changed
0
0
Below
0
0
Above
0
0
InBetween
0
0
1
: change behavior type
11 : change threshold alarm level
2
: change behavior interval
12 : change changed alarm
3
: change threshold boundary level 13 : change belowalarm
4
: change custom unit
14 : change abovealarm
5
: change custom timebase
15 : change inBetween alarm
6
: change custom low
16 : apply threshold alarm changes
7
: change custom high
17 : cancel threshold alarm changes
8
: change custom buffer
18 : return to previous page
9
: apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]
7
Note
To ensure that your threshold setting configuration takes effect, remember to change the
threshold boundary level to Custom using option 3, and then apply the threshold
boundary level settings using option 16.