HP StorageWorks 2/16V Brocade Secure Fabric OS Administrator's Guide (53-10002 - Page 113

Miscellaneous Commands, zoneDelete

Page 113 highlights

B Table B-2 Zoning Commands (Continued) Command Primary FCS Backup FCS Non-FCS Switch Switch Switch faZoneShow Yes Yes No lsanzoneshow Yes No No zone Yes No No zoneAdd Yes No No zoneCreate Yes No No zoneDelete Yes No No zoneObjectRename Yes No No zoneRemove Yes No No zoneShow Yes No No Miscellaneous Commands Table B-3 lists which miscellaneous commands, including management server and SNMP commands, can be executed on which switches. Commands not listed here (or in the preceding two tables) can be executed on any switch. Table B-3 Miscellaneous Commands Command Primary FCS Switch Backup FCS Switch Non-FCS Switch agtcfgDefault Yes Yes (except cannot modify community strings) Yes (except cannot modify community strings) agtcfgSet Yes configUpload Yes Yes (except cannot modify community strings) Yes Yes (except cannot modify community strings) Not recommended. The zoning and Secure Fabric OS configurations are not uploaded if entered on a non-FCS switch. date Yes Yes (read only) Yes (read only) date msCapabilityShow msConfigure msPlatShow Yes No No Yes Yes (except ACL does not display) Yes Yes Yes (except ACL does not display) Yes Yes Yes (except ACL does not display) Yes Secure Fabric OS Administrator's Guide B-7 Publication Number: 53-1000244-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

Secure Fabric OS Administrator’s Guide
B-7
Publication Number: 53-1000244-01
B
Miscellaneous Commands
Table B-3
lists which miscellaneous commands, including management server and SNMP commands,
can be executed on which switches. Commands not listed here (or in the preceding two tables) can be
executed on any switch.
faZoneShow
Yes
Yes
No
lsanzoneshow
Yes
No
No
zone
Yes
No
No
zoneAdd
Yes
No
No
zoneCreate
Yes
No
No
zoneDelete
Yes
No
No
zoneObjectRename
Yes
No
No
zoneRemove
Yes
No
No
zoneShow
Yes
No
No
Table B-3
Miscellaneous Commands
Command
Primary FCS Switch
Backup FCS Switch
Non-FCS Switch
agtcfgDefault
Yes
Yes (except cannot
modify community
strings)
Yes (except cannot
modify community
strings)
agtcfgSet
Yes
Yes (except cannot
modify community
strings)
Yes (except cannot
modify community
strings)
configUpload
Yes
Yes
Not recommended.
The zoning and
Secure Fabric OS
configurations are not
uploaded if entered on
a non-FCS switch.
date
Yes
Yes (read only)
Yes (read only)
date
<
operand to set
time
>
Yes
No
No
msCapabilityShow
Yes
Yes
Yes
msConfigure
Yes (except ACL does
not display)
Yes (except ACL does
not display)
Yes (except ACL does
not display)
msPlatShow
Yes
Yes
Yes
Table B-2
Zoning Commands
(Continued)
Command
Primary FCS
Switch
Backup FCS
Switch
Non-FCS
Switch