HP StorageWorks 2/16V HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Instal - Page 43

Assembling the inner rails, Phillips pan-head SEMS screws as shown

Page 43 highlights

Installing the SAN Switch a. Assemble the two inner rails (one on each side) to the switch using the appropriate number (from step 5 on page 42) of #8-32 x 5/16-inch Phillips pan-head SEMS screws as shown in Figure 10. Note: The rail kit provides fourteen #8-32 x 5/16-inch screws for assembling the inner rails. Each switch requires a different number of these screws. For example, Figure 10 shows the an inner rail being attached to the SAN Switch 2/16V with five screws. Attaching both inner rails requires ten screws. 0012a Figure 10: Assembling the inner rails Note: For factory integration only, tighten the #8-32 x 5/16-inch Phillips pan-head SEMS screws and torque between 6 to 8 inch-pounds. SAN Switch 2/8V, 2/16V and 2/16N Installation Guide 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

Installing the SAN Switch
43
SAN Switch 2/8V, 2/16V and 2/16N Installation Guide
a.
Assemble the two inner rails (one on each side) to the switch using the
appropriate number (from
step 5
on page 42) of #8-32 x 5/16-inch
Phillips pan-head SEMS screws as shown in
Figure 10
.
Note:
The rail kit provides fourteen #8-32 x 5/16-inch screws for assembling the inner
rails. Each switch requires a different number of these screws. For example,
Figure 10
shows the an inner rail being attached to the SAN Switch 2/16V with five screws.
Attaching both inner rails requires ten screws.
Figure 10:
Assembling the inner rails
Note:
For factory integration only, tighten the
#8-32 x 5/16-inch Phillips pan-head
SEMS screws
and torque between 6 to 8 inch-pounds.
0012a