Assembling the inner rails on a SAN Switch with plenum, The components
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Installing the SAN Switch b. For the SAN Switch 2/8V, assemble the two inner rails (one on each side) to the switch and plenum using the appropriate number (from step 5 on page 42) of #8-32 x 5/16-inch Phillips pan-head SEMS screws as shown in Figure 11. Note: The plenum is a required part of this installation when the SAN switch 2/8V, SAN switch 2/16V or 2/16N are installed in an HP 9000 or 10000 serires, System/e or comparable EIA cabinet. The plenum allows air to dissipate at the rear of the rack, preventing overheating. If the Plenum is not pre-installed, refer to step b on page 44 for instructions. 1 2 0013a Figure 11: Assembling the inner rails on a SAN Switch with plenum The components in Figure 11 include: 1 Plenum 2 Switch 7. Insert the switch with the attached inner rails into the outer rails. 44 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide