HP StoreOnce 4430 HP StoreOnce 2600, 4200 and 4400 Backup system Maintenance a - Page 19
Procedure
View all HP StoreOnce 4430 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Figure 6 FBWC module LEDs Procedure 1. 2. Remove the cover from the HP StoreOnce Backup system, as described in the appropriate HP ProLiant Maintenance and Service guide, and locate the FBWC (see previous section). Look at the LEDs on the FBWC. If the LEDs are blinking amber they module should be replaced. NOTE: For a detailed description of the LEDs, refer to the "HP Smart Arrays for HP ProLiant Servers user guide". 3. Follow the instructions in the "HP Smart Arrays for HP ProLiant Servers user guide" to remove and dispose of the old FBWC and to replace it with the new one. 4. Replace the cover and power up the HP StoreOnce Backup system. Check the status of the system on the Hardware Problem Report, which should now be blank. If this does not resolve the problem, the associated RAID card may need replacing. Replacing the battery/flash capacitor module 19