HP Surestore 28/48-Slot with DLT7000 HP SureStore Fibre Channel SCSI Bridge 21 - Page 32
Fibre Bridge Connection, Expanded, Configuration Example DLT Libraries Only
View all HP Surestore 28/48-Slot with DLT7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
CAUTION Setting Up the Fibre Bridge Installing Cables Fibre Bridge Connection, Expanded Configuration Example (DLT Libraries Only) 1. Properly shut down all peripheral devices that will be connected to the Fibre Bridge, including the hub(s). Check with the system administrator before turning off power to either hubs or libraries. Failure to turn off all power could result in damage to the devices. 2. Connect a SCSI cable from bus 1 on the Fibre Bridge to bus 1 on the library one. For a two-drive library, connect a SCSI cable from bus 2 on the Fibre Bridge to bus 2 on the library. 3. Connect the optical cable from the Fibre Bridge to the hub. 4. Connect an optical cable from the hub to each host system. If you have a 6-8 host system, you will need an additional hub. (See Figure 2-3 and Figure 2-4 for examples of expanded configurations.) 5. Connect the power cord from Fibre Bridge one to an grounded outlet. 6. Confirm that all cable ends are connected securely and both ends of each SCSI bus are properly terminated, as shown in Figure 2-4 or Figure 2-5 on page 2-10. 7. See poweron instructions in Chapter 3. 2- 8 Chapter 2