Honeywell 3800LR-12 User Manual - Page 145
Standard Cable Pinouts, Laser Output Only Laser Compatible Bar Image - hand held
View all Honeywell 3800LR-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Standard Cable Pinouts Laser Output Only (Laser Compatible Bar Image) 3800/3900 User's Guide Conventional laser data format is provided at the modular connector in the scanner handle. The interface cable is terminated with a 10 pin modular plug, and a 9 pin Type D (squeeze to release) connector that is compatible with all Hand Held Products terminals. 10 Pin Modular Plug onnects to the scanner handle 1 Turn on good read or LED beeper 2 Trigger signal to decoder 3 Laser enable 4 Supply ground 5 6 Digital bar code data output 7 Power connection (Refer to table on page 13-1) 8 9 Start of scan 10 Start of scan 1 Digital bar code data output 2 Turn on good read LED or beeper 3 ◆ N/C 4 Trigger signal to decoder 5 6 Laser enable 7 Supply ground 8 Cord shield 9 5 Volt power connection ◆ 9 Pin Type D Female connects to your terminal ◆ Pins 4 and 9 are populated depending on power supply voltage option. Some decoders may have +12V on pins 4 or 9. Connect to +5VDC ONLY! 13 - 3