Honeywell 3800LR-12 User Manual - Page 57

Interfunction Delay, Intermessage Delay, 2nd Scan Transmission

Page 57 highlights

Interfunction Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between the transmission of each segment of the message string. You can program up to 99 steps (of 5 ms each). Scan the Interfunction Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the inside back cover, scan the Interfunction Delay bar code, scan the correct digits, and Save again. Prefix Scanned Data Suffix STX 1 HT 2 3 4 5 CR LF Interfunction Delays Interfunction Delay To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover. Intermessage Delay This is a delay of up to 495 milliseconds (in multiples of 5) placed between each scan transmission. You can program up to 99 steps (of 5 ms each). Scan the Intermessage Delay bar code below, then scan the number of steps, and the SAVE bar code from the inside back cover. Note: If you make an error while scanning the digits (before scanning Save), scan Discard on the inside back cover, scan the Intermessage Delay bar code, scan the correct digits, and Save again. 1st Scan Transmission 2nd Scan Transmission Intermessage Delay Intermessage Delay To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 00. Scan the SAVE bar code from the inside back cover. 3800/3900 User's Guide 4 - 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

3800/3900 User’s Guide
4 - 9
Interfunction Delay
This is a delay of up to 495 milliseconds (in multiples of 5) placed between the
transmission of each segment of the message string. You can program up to 99
steps (of 5 ms each).
Scan the Interfunction Delay bar code below, then scan
the number of steps, and the
SAVE
bar code from the inside back cover.
Note:
If you make an error while scanning the
digits (before scanning Save), scan Discard on the inside back cover,
scan the Interfunction Delay bar code, scan the correct digits, and Save
again
.
To remove this delay, scan the Interfunction Delay bar code, then set the number
of steps to 00.
Scan the
SAVE
bar code from the inside back cover.
Intermessage Delay
This is a delay of up to 495 milliseconds (in multiples of 5) placed between each
scan transmission.
You can program up to 99 steps (of 5 ms each).
Scan the
Intermessage Delay bar code below, then scan the number of steps, and the
SAVE
bar code from the inside back cover.
Note:
If you make an error while scanning the digits (before scanning Save),
scan Discard on the inside back cover, scan the Intermessage Delay bar
code, scan the correct digits, and Save again
.
To remove this delay, scan the Intermessage Delay bar code, then set the
number of steps to 00.
Scan the
SAVE
bar code from the inside back cover.
Interfunction Delays
Prefix
Scanned Data
Suffix
1
2
34
5
STX
HT
CR
LF
Interfunction Delay
2nd Scan Transmission
1st Scan Transmission
Intermessage Delay
Intermessage Delay