OCIA Interface, NCR OCIA Short Format (8 Bit) Interface, Symbology, Prefix
View all Honeywell 3800LR-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
OCIA Interface Note: The OCIA interfaces are only available on the 3800XX-11 and 3800XX11E models. Scan one of the following "Plug and Play" codes to program the 3800 for Generic OCIA, NCR OCIA Short Format (8 bit), NCR OCIA Long Format (9 bit), and Nixdorf OCIA. Note: After scanning one of these codes, you must re-boot the cash register. Generic OCIA Interface The Generic OCIA bar code also programs the following prefixes for each symbology: Symbology EAN 8 EAN 13 UPC A UPC E Prefix 06 06 06 01 05 NCR OCIA Short Format (8 Bit) Interface NCR OCIA Short Format (8 Bit) Interface The NCR OCIA Short Format (8 Bit) bar code also programs the following prefixes for each symbology: Symbology EAN 8 EAN 13 UPC A UPC E Prefix 0F 0F 0F 0A 0E 3800/3900 User's Guide 1 - 11