Honeywell 3800LR-12 User Manual - Page 73
Concatenation, Codabar Message Length, Enable, Require
View all Honeywell 3800LR-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Concatenation Codabar supports symbol concatenation. When you Enable concatenation, the scanner looks for a Codabar symbol having a "D" start character, adjacent to a symbol having a "D" stop character. In this case the two messages are concatenated into one with the "D" characters omitted. Default = On. Character Start Stop Start Stop Codabar A12D D34A Select Require to prevent the scanner from decoding a lone Codabar symbol. * On Off Require Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length 3800/3900 User's Guide 7 - 5