LYNXR-I Installation and Setup Guide Interactive Menu Mode Programming (✻56, ✻80, ✻81, ✻83, ✻84, ✻85) Press [✻] + interactive mode No. (i.e., ✻56). The keypad will display the first of a series of prompts. A detailed procedure (with displays of prompts) is provided in later sections of this manual. Interactive Mode Used to Program ✻56 Enhanced Zone Programming Mode Zone characteristics, report codes, and serial numbers ✻80 Device Programming Menu Mode Powerline Carrier Devices ✻81 Zone List Menu Mode Zone Lists for powerline carrier activation ✻83 Enhanced Sequential Mode 5800 Series transmitter serial numbers ✻84 Assign Zone Voice Descriptors Voice descriptors for each zone ✻85 Record Custom Voice Descriptors Up to 5 custom voice descriptors for zones Loading Factory Defaults To load the factory defaults, enter the Programming mode, press ✻97, then press number 1, 2, 3, or 4 to select from default tables 1-4 at the back of this manual, or press "0" if you are not selecting a default table. If a default table is loaded, any data that has already been programmed into the system will be changed according to the default table selected! ✻96 resets all subscriber account numbers and CSID in preparation for an initial download. Exiting Program Mode ✻98 inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code. ✻99 allows re-entry into the Expert Program mode using Installer Code (4112) + 800 or into the Voice Prompt Programming mode using Installer Code (4112) + 888. Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset delay, press [#] + [0]. Pass-Thru Programming This mode allows the Installer to use the LYNXR-I keypad and display to program the communications device that is connected to the LYNXR-I. Refer to the communications device's installation instruction to determine whether this feature is supported. Entering Pass-Thru Programming mode 1. After power-up, enter the Installer Code (4112) + 899. 2. Once you have entered Pass-Thru Programming mode "PtP" will be displayed on the keypad. 3. Refer to the Installation Instructions for the LRR/IP Communications Device being installed for additional programming information. LYNXR-I will abort this mode: • When it receives an abort command from the new communications device. • If it fails to communicate with an communications device after 20 attempts. • 30 minutes after the last key has been pressed. - 17 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

LYNXR-I Installation and Setup Guide
- 17 -
Interactive Menu Mode Programming
(
56,
80,
81,
83,
84,
85)
Press
[
]
+
interactive mode No.
(i.e.,
56). The keypad will display the first of a series of prompts. A detailed
procedure (with displays of prompts) is provided in later sections of this manual.
Interactive Mode
Used to Program
56 Enhanced Zone Programming Mode
Zone characteristics, report codes, and serial numbers
80 Device Programming Menu Mode
Powerline Carrier Devices
81 Zone List Menu Mode
Zone Lists for powerline carrier activation
83 Enhanced Sequential Mode
5800 Series transmitter serial numbers
84 Assign Zone Voice Descriptors
Voice descriptors for each zone
85 Record Custom Voice Descriptors
Up to 5 custom voice descriptors for zones
Loading Factory Defaults
To load the factory defaults, enter the Programming mode, press
97, then press number 1, 2, 3, or 4 to
select from default tables
1-4 at the back of this manual, or press “0” if you are not selecting a default table.
If a default table is loaded, any data that has already been programmed into the system will be changed according to the
default table selected!
96
resets all subscriber account numbers and CSID in preparation for an initial download.
Exiting Program Mode
98
inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code.
99
allows re-entry into the Expert Program mode using
Installer Code (4112) + 800
or into the
Voice
Prompt Programming
mode using
Installer Code (4112) + 888
.
Note:
After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset
delay, press [#] + [0].
Pass-Thru Programming
This mode allows the Installer to use the LYNXR-I keypad and display to program the communications
device that is connected to the LYNXR-I. Refer to the communications device’s installation instruction to
determine whether this feature is supported.
Entering Pass-Thru Programming mode
1.
After power-up, enter the
Installer Code (4112) + 899.
2.
Once you have entered Pass-Thru Programming mode “PtP” will be displayed on the keypad.
3. Refer to the Installation Instructions for the LRR/IP Communications Device being installed for
additional programming information.
LYNXR-I will abort this mode:
When it receives an abort command from the new communications device.
If it fails to communicate with an communications device after 20 attempts.
30 minutes after the last key has been pressed.