Honeywell WAVE2EX Setup Guide - Page 64

ZONE LIST FOR OUTPUT DEVICES DEFAULT TABLE: Applies To Default Table 1 - 4.

Page 64 highlights

LYNXR-I Installation and Setup Guide Programming Default Tables ✻56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4 Zone No. Zone Type Alarm Code Input Type Loop Number Zone Descriptor 2 1 1,0 3 (RF) 2 47, 04 (FRONT DOOR) 3 1 1,0 3 (RF) 2 33, 04 (BACK DOOR) 4 3 1,0 3 (RF) 2 80 (WINDOW) 5 3 1,0 3 (RF) 2 80 (WINDOW) 6 3 1,0 3 (RF) 2 80 (WINDOW) 7 3 1,0 3 (RF) 2 80 (WINDOW) 8 10 1,0 3 (RF) 1 56 (MOTION DETECTOR) 9 9 1,0 3 (RF) 1 22, 02 (SMOKE DETECTOR) 26 21 1,0 5 (BR) 3 27 22 1,0 5 (BR) 2 28 23 0,0 5 (BR) 4 29 23 0,0 5 (BR) 1 30 21 1,0 5 (BR) 3 31 22 1,0 5 (BR) 2 32 23 0,0 5 (BR) 4 33 23 0,0 5 (BR) 1 92 --- 1,0 --- --- 99 6 1,0 --- --- NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic ✻80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 4 (devices 2-7 have no default values) Start Stop Zone Type Restore of Zone type Device Number Action Event Zone List System Operation Zone List System operation 1 2 2 1 2 8** 2 33 36 ** NOTE: If using an X10 Powerhouse Security SH10A siren as device 8, you must change the device action default to "3" if using default table 4. ✻80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 1 and 2 (devices 1-7 have no default values) Start Stop Zone Type Restore of Zone type Device Number Action Event Zone List System Operation Zone List System operation 8** 2 33 36 ✻81 ZONE LIST FOR OUTPUT DEVICES DEFAULT TABLE: Applies To Default Table 1 - 4. Zone List 1 28, 32 Zone List 2 29, 33 Zone List 3 2, 3 - 64 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

LYNXR-I Installation and Setup Guide
- 64 -
Programming Default Tables
56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4
Zone No.
Zone Type
Alarm Code
Input Type
Loop Number
Zone Descriptor
2
1
1,0
3 (RF)
2
47, 04 (FRONT DOOR)
3
1
1,0
3 (RF)
2
33, 04 (BACK DOOR)
4
3
1,0
3 (RF)
2
80 (WINDOW)
5
3
1,0
3 (RF)
2
80 (WINDOW)
6
3
1,0
3 (RF)
2
80 (WINDOW)
7
3
1,0
3 (RF)
2
80 (WINDOW)
8
10
1,0
3 (RF)
1
56 (MOTION DETECTOR)
9
9
1,0
3 (RF)
1
22, 02 (SMOKE DETECTOR)
26
21
1,0
5 (BR)
3
27
22
1,0
5 (BR)
2
28
23
0,0
5 (BR)
4
29
23
0,0
5 (BR)
1
30
21
1,0
5 (BR)
3
31
22
1,0
5 (BR)
2
32
23
0,0
5 (BR)
4
33
23
0,0
5 (BR)
1
92
---
1,0
---
---
99
6
1,0
---
---
NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic
80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 4 (devices 2-7 have no default values)
Start
Stop
Device Number
Action
Event
Zone List
Zone Type
System Operation
Restore of
Zone List
Zone type
System operation
1
2
2
1
2
8**
2
33
36
**
NOTE:
If using an X10 Powerhouse Security SH10A siren as device 8, you must change the device action default to “3” if using default
table
4.
80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 1 and 2 (devices 1-7 have no default values)
Start
Stop
Device Number
Action
Event
Zone List
Zone Type
System Operation
Restore of
Zone List
Zone type
System operation
8**
2
33
36
81 ZONE LIST FOR OUTPUT DEVICES DEFAULT TABLE: Applies To Default Table 1 - 4.
Zone List 1
28, 32
Zone List 2
29, 33
Zone List 3
2, 3