Honeywell WAVE2EX Setup Guide - Page 28

Other Programming Commands

Page 28 highlights

LYNXR-I Installation and Setup Guide Data Field Descriptions DOWNLOAD INFORMATION (✻94, ✻95) ✻94 ✻95 Download Call Back Phone Number Enter up to 20 digits as follows: 0-9, # +11 for "*", # + 12 for "#", # + 13 for a pause. Ring Detection Count For Downloading/ Remote Phone Control 0 = disable station initiated download and remote phone 1-14 = number of rings before control picks up phone line 15 = defeat answering machine This is the phone number the control will use to call back the downloading computer. Do not fill unused spaces. End field by pressing ✻. To clear entries from field, press ✻94✻. Enter "15" to select defeat answering machine mode. If an answering machine is on the premises, you need to dial the premises and hang up on the first ring. Wait at least five (5) seconds (but no more than 22 seconds) and dial the premises phone number again. The control will pick up and announce "SYSTEM ENTER CODE" every three seconds. Note: To enter a number higher than 9 you must first press the [#] key. OTHER PROGRAMMING COMMANDS ✻56 ✻80 ✻81 ✻83 ✻84 ✻85 ✻96 ✻97 ✻98 ✻99 ENHANCED ZONE PROGRAMMING MODE Interactive menu mode used for programming zone attributes and report codes. Refer to the ✻56 Enhanced Zone Programming Mode section for procedure. DEVICE PROGRAMMING MENU MODE Interactive menu mode for programming Powerline Carrier Devices. Refer to the ✻80 Device Programming Menu Mode section for detailed procedure. ZONE LISTS MENU MODE Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the ✻81 Zone List Menu Mode section for detailed procedure. ENHANCED SEQUENTIAL MODE Interactive menu mode used to enter RF transmitter serial numbers. Refer to the ✻83 Enhanced Sequential Mode section for detailed procedure. ASSIGN ZONE VOICE DESCRIPTORS Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced whenever the system announces an event involving a zone. RECORD CUSTOM VOICE DESCRIPTORS Interactive menu mode used to record custom descriptors for use with each zone. INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO. FOR DOWNLOADING Pressing ✻96 initializes the system for downloading. SET ALL PROGRAM FIELDS TO 1 OF 4 SETS OF DEFAULT VALUES See Default Tables at the end of this manual. EXITS PROGRAMMING MODE Prevents re-entry by: Installer Code + 8 + 0 + 0; allows re-entry only by Power-up, then [✻] and [#]. EXITS PROGRAMMING MODE Allows re-entry to program mode by: Installer Code + 8 + 0 + 0; or by Power-up, then [✻] and [#]. - 28 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

LYNXR-I Installation and Setup Guide
- 28 -
Data Field Descriptions
DOWNLOAD INFORMATION (
94,
95)
94
Download Call Back Phone Number
Enter up to 20 digits as follows: 0–9, # +11 for “
*
”, #
+ 12 for “#”, # + 13 for a pause.
This is the phone number the control will use to call back the downloading
computer.
Do not fill unused spaces. End field by pressing
.
To clear entries from
field, press
94
.
95
Ring Detection Count For Downloading/
Remote Phone Control
0 = disable station initiated download and remote
phone
1-14 = number of rings before control picks up phone
line
15 = defeat answering machine
Enter “15” to select defeat answering machine mode. If an
answering machine is on the premises, you need to dial the
premises and hang up on the first ring. Wait at least five (5)
seconds (but no more than 22 seconds) and dial the premises
phone number again. The control will pick up and announce
“SYSTEM ENTER CODE” every three seconds.
Note:
To enter a number higher than 9 you must first press the [#] key.
OTHER PROGRAMMING COMMANDS
56
ENHANCED ZONE PROGRAMMING MODE
Interactive menu mode used for programming zone attributes and report codes. Refer to the
56
Enhanced Zone Programming Mode
section for procedure.
80
DEVICE PROGRAMMING MENU MODE
Interactive menu mode for programming Powerline Carrier Devices. Refer to the
80 Device
Programming Menu Mode
section for detailed procedure.
81
ZONE LISTS MENU MODE
Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the
81
Zone List Menu Mode
section for detailed procedure.
83
ENHANCED SEQUENTIAL MODE
Interactive menu mode used to enter RF transmitter serial numbers. Refer to the
83 Enhanced
Sequential Mode
section for detailed procedure.
84
ASSIGN ZONE VOICE DESCRIPTORS
Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced
whenever the system announces an event involving a zone.
85
RECORD CUSTOM VOICE DESCRIPTORS
Interactive menu mode used to record custom descriptors for use with each zone.
96
INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO. FOR
DOWNLOADING
Pressing
96 initializes the system for downloading.
97
SET ALL PROGRAM FIELDS TO 1 OF 4 SETS OF DEFAULT VALUES
See Default Tables at the end of this manual.
98
EXITS PROGRAMMING MODE
Prevents re-entry by: Installer Code + 8 + 0 + 0; allows re-entry only by Power-up, then [
] and [#].
99
EXITS PROGRAMMING MODE
Allows re-entry to program mode by: Installer Code + 8 + 0 + 0; or by Power-up, then [
] and [#].