Honeywell WAVE2EX Setup Guide - Page 9

Connecting AlarmNet 7845GSM* / 7845i-GSM, Connecting AlarmNet 7845i-ENT/7845i

Page 9 highlights

LYNXR-I Installation and Setup Guide AlarmNet 7845GSM*, 7845i-GSM*, 7845i-ENT or 7845i, Communications Device  The 7845i-ENT/7845i and 7845CV2 can not be used for installations requiring 24-hour standby. 1. Connect the 4-wire communications cable to the LRR/IP Communications port on the LYNXR-I. 2. Connect the four wires to the specific Communications device as shown in the accompanying figures. 3. If you are installing a 7845GSM or 7845i-GSM you must also install a jumper between terminals 2 and 3 on the communications device. 4. Connect the device to the Internet via a cable/DSL modem and router or to an Intranet (LAN) via the appropriate Ethernet connection, if applicable. YEL RED BLK GRN 4-WIRE CABLE (N4632-4) LRR/IP COMMUNICATIONS PORT RED BLK YEL GRN TB1 1 2 43 ECP (+) VOLTAGE INPUT 4 GND 5 Z1/Z2 OR DATA IN 6 Z3 OR DATA OUT DATA OUT NC +12 VDC GND DATA IN LYNXR-I CONTROL PANEL 7845GSM / 7845i-GSM LYNX STANDARD CAPACITY BATTERY LYNX SUPER HIGH CAPACITY (OPTIONAL) REQUIRED FOR BATTERY 24-HR BACKUP Connecting AlarmNet 7845GSM* / 7845i-GSM* 7845i-GSM-010-V0 * When available. The AlarmNet 7845GSM and 7845i-GSM modules have not been evaluated by UL. 4-WIRE CABLE (N4632-4) 7845i-ENT / 7845i (+) VOLTAGE INPUT GND DATA OUT DATA IN YEL RED BLK GRN DATA OUT NC +12 VDC GND DATA IN TB 1 RED BLK GRN YEL LRR/IP COMMUNICATIONS PORT LYNXR-I CONTROL PANEL RED BLK GRN YEL LYNX STANDARD CAPACITY BATTERY Connecting AlarmNet 7845i-ENT/7845i 07000-013-V2 - 9 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

LYNXR-I Installation and Setup Guide
- 9 -
AlarmNet 7845GSM*, 7845i-GSM*, 7845i-ENT or 7845i, Communications Device
The 7845i-ENT/7845i and 7845CV2 can not be used for installations requiring 24-hour standby.
1. Connect the 4-wire communications cable to the LRR/IP Communications port on the LYNXR-I.
2. Connect the four wires to the specific Communications device as shown in the accompanying figures.
3.
If you are installing a 7845GSM or 7845i-GSM you must also install a jumper between terminals 2 and 3 on the
communications device.
4.
Connect the device to the Internet via a cable/DSL modem and router or to an Intranet (LAN) via the appropriate Ethernet
connection, if applicable.
7845GSM / 7845i-GSM
LYNX
SUPER HIGH
CAPACITY
BATTERY
(OPTIONAL)
REQUIRED FOR
24-HR BACKUP
7845i-GSM-010-V0
GND
Z3 OR DATA OUT
Z1/Z2 OR DATA IN
ECP (+) VOLTAGE INPUT
RED
BLK
GRN
YEL
RED
BLK
GRN
YEL
4
5
6
3
5
4
4-WIRE CABLE (N4632-4)
1
2
TB1
LRR/IP COMMUNICATIONS PORT
LYNXR-I CONTROL PANEL
NC
+12 VDC
GND
DATA IN
DATA OUT
LYNX
STANDARD
CAPACITY
BATTERY
Connecting AlarmNet 7845GSM* / 7845i-GSM*
* When available. The AlarmNet 7845GSM and 7845i-GSM modules have not been evaluated by UL.
7845i-ENT / 7845i
07000-013-V2
GND
DATA IN
DATA OUT
(+) VOLTAGE INPUT
RED
BLK
GRN
YEL
RED
BLK
GRN
YEL
TB 1
LYNXR-I CONTROL PANEL
NC
RED
BLK
GRN
YEL
+12 VDC
GND
DATA IN
DATA OUT
4-WIRE CABLE (N4632-4)
LYNX
STANDARD
CAPACITY
BATTERY
LRR/IP COMMUNICATIONS PORT
Connecting AlarmNet 7845i-ENT/7845i