Honeywell WAVE2EX Setup Guide - Page 71
Lynxr-i Summary Of Connections - size
UPC - 781410215504
View all Honeywell WAVE2EX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Notes: Connection of the fire alarm signal to a fire alarm headquarters or a central station shall be permitted with the approval of the local authority having jurisdiction. The burglar alarm signal shall not be connected to a police emergency number. The System must be checked by a qualified technician once every three years. - 71 - UL INSTALLATIONS THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS TO HANDSET INCOMING ALL OUTPUT CIRCUITS ARE POWER LIMITED. MUST BE #26 GAUGE PHONE LINE PHONE LINE EARTH GROUND PHONE FUTURE USE GND SOUNDERS PLCD AC EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL. RJ11 8 POSITION JACK WARNING: TO PREVENT RISK OF SHOCK DISCONNECT TELEPHONE LINE AT TELECOM JACK BEFORE SERVICING THIS UNIT. 1 23 4 56 TIP RING TIP RING 7 8 ( ) INTERNAL 7845i-L* MODULE ONLY STANDARD/HIGH CAPACITY BATTERY CONNECTOR LOCAL SOUNDER DISABLE SHUNT REMOVE TO DISABLE SUPER HIGH CAPACITY BATTERY CONNECTOR ALARMNET LRR/IP COMMUNICATIONS PORT INCOMING TELEPHONE LINE EARTH GROUND PREMISES TELEPHONE WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM FUTURE USE DATA IN GND DATA OUT POWERLINE CARRIER DEVICES 9 10 11 12 13 14 15 DATA SYNC OUT IN PIEZO BELL 6-14VDC 30mA max. 6-14VDC 120mA max. (e.g. WAVE2EX) 16 FCC ID: CFS8DLLYNXREN-3 (LYNXR-I) COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No. 5GBUSA-25623-AL-E RINGER EQUIVALENCE: 0.6B NOTE USE ONLY THE K10145X10 OR K10145CN CLASS 2 TRANSFORMERS PROVIDED TO 24HR 110VAC UNSWITCHED OUTLET AC AC SYNC COM DATA K10145X10 PLUG-IN TRANSFORMER 9VAC, 25VA X10 ONLY CONNECTIONS THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE AND NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2 (NATIONAL FIRE PROTECTION ASSOC., BATTERYMARCH PARK, QUINCY, MA 02269). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. THE LYNXR-I CONTROL IS COMPATIBLE WITH THE FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS: P/N LYNXRCHKIT-SC P/N LYNXRCHKIT-HC P/N LYNXRCHKIT-SHA REPLACE EVERY FOUR YEARS GND SOUNDERS 9 PLCD AC 13 14 15 16 FOR CANADIAN INSTALLATIONS TO 24HR 110VAC UNSWITCHED OUTLET K10145CN PLUG-IN TRANSFORMER 9VAC, 25VA YELLOW BLACK THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. *WHEN AVAILABLE LYNXR-I ALSO COMPLIES WITH THE FOLLOWING: CANADIAN STANDARDS ASSOCIATION (CSA) C22.1, CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540 INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS. RED GREEN 4-WIRE MODULAR PHONE CORD WITH FLYING LEADS 1 2 3 4 PL513 POWERLINE INTERFACE (IF USING X10 DEVICES) LYNXR-I SUMMARY OF CONNECTIONS 07000-016-V1