Intermec CS40 Intermec Terminal Emulator (ITE) User Guide - Page 72
Configuring for UDP Plus
View all Intermec CS40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Chapter 2 - Configuring and Managing ITE Configuring for UDP Plus Note: When UDP Plus is enabled, it applies to all sessions. ITE does not support mixed TCP/IP and UDP Plus sessions. 1 Open the Intermec Terminal Emulation main menu in Intermec Settings. For help, see "To configure ITE directly on the computer" on page 21. 2 Tap UDP+ Options. 3 Select Enable UDP+. Enabling UDP Plus The UDP+ Options list includes global UDP Plus settings. For information on these global settings, see the next table. Global UDP Plus Configuration Item Descriptions Item Description Values UDP+ Port Max Retries Port to access the UDP Plus server. Maximum number of times to retry the connection before starting the watchdog timer. Range is 0 to 65535. Default is 5555. Range is 1 to 99. Default is 7. WD Rcv Timeout WD Send Timeout Ack Lower Bound Ack Upper Bound After the maximum number of retries Range is 1 to 3600 ms. is reached, this is the amount of time Default is 45. that ITE waits before closing the connection when receiving. After the maximum number of retries Range is 1 to 3600 ms. is reached, this is the amount of time Default is 20. that ITE waits before closing the connection when sending. Amount of time that ITE waits before Range is 200 to 2000 ms. expecting an acknowledgement. Default is 300. Amount of time that ITE waits when Range is 2000 to 60000 ms. expecting an acknowledgement. Default is 5000. 60 Intermec Terminal Emulator (ITE) User Guide