JVC RMP-2580U RM-P2580 Dome Controller Instructions (1148KB) - Page 21
JVC RMP-2580U - Remote Controller For Color Domes Manual
View all JVC RMP-2580U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
4. CONNECTIONS APPLIED SYSTEM (B MODE) This system accepts the connection of up to 16 cameras. The video is recorded by means of a frame switcher. When an alarm input is required to the SW-D7000/ SW-D8000, be sure to use the ALM OUTPUT of the I/O terminal of RM-P2580. ● Read the "Instruction Manual" for each piece of equipment to be connected before performing the connection. NOTES ● When the +, -, Auto, F1~3 buttons are pressed quickly and consecutively, it may happen that the camera display does not correspond to the video output. If this is the case, press the buttons slowly and precisely. ● The AUTO LED of the RM-P2580 will not light up, even during AUTO SEQUENCE. Setting Procedure 1. 2. 3. Connect all the equipment. (All of the cameras must be synchronized) Set the system mode selection to B Mode, and set the rear DIP SW1 to "ON". To set a camera ( REF. : Instruction Manual of the camera being used) · Match the ID with the VIDEO INPUT number. · Set to MULTIDOROP and DUPLEX Using the SERIAL-2 item, set to the frame switcher. ( REF. : page 29) Set the alarm to the PRIORITY mode for alarm signal input. Set the " PRIORITY" in the ALARM SCREEN to "ALARM". ( REF. : page 32) Frame switcher setting ● Set the Baud rate to 9600 bps. Set the SW-D7000/SW-D8000 communications menu of RS232 to 9600 bps. ● Set the alarm time to that of RM-P2580. Adjust the Alarm timeout of the timeout menu inside the alarm latch menu of SW-D7000/SW-D8000 to the ALARM TIME of RM-P2580. Preset positions ( REF. : page 27) Operational setting values can be changed as required. · P/T SPEED: 8 STEPS ( REF. : page 29) Check the ALARM INPUT time set value. · DATA I/O screen: 16ALM IN or 8 ALM IN ( REF. : page 30) · ALARM screen ( REF. : page 32) · TERMINAL item ( REF. : page 31) 4. 5. 6. CAMERA 1 AC24V ID:1 CAMERA 2 AC24V 7. 8. 9. ID:2 CAMERA 3 AC24V 10. ALARM INPUT TIME setting required for each camera ID:3 MONITOR 1 2 3 4 5 6 7 8 V.IN MONITOR-A OUTPUT TO CAMERA RX+ RX- TX+ TXRX RX TX TX RS-232C CAM IN CAM SW OUT REC STOP REC CHECK VCR OUTPUT VIDEO INPUT MONITOR B OUTPUT VIDEO INPUT 1 COM 1 2 3 4 5 6 7 8 SEREAL-2 SERIAL-1 SERIAL-2 6 7 8 MONITOR MONITOR OUTPUT OUTPUT 1 2 TO CAMERA DATA I / O UNIT CAMERA COM 9/1 10/2 11/3 12/4 13/5 14/6 15/7 16/8 COM AUTO ALARM COM SW COM POWER ON OFF REC EJECT OPERATE OPERATE 1 2 3 4 VIDEO INPUT 5 AC`INPUT 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 VIDEO OUTPUT 6 7 8 TIMELAPSE VCR MONITOR OUTPUT 1 RM-P2580 SERIAL-2 connector (D-sub 9 pin, female) Signal name Pin No. SW-D7000/SW-D8000 Alarm connector (D-sub 9 pin, male) Pin No. Signal name Set Pin 1 to "ON" for B Mode. RM-P2580 V.IN R X D T X D G N D 2 3 5 2 3 5 R X T X G N D MASTER MONITOR When connecting a frame switcher, be sure to read its "Instruction manual" before connecting it. 21