Konica Minolta magicolor 4750EN/4750DN magicolor 4750EN/magicolor 4750DN User - Page 87
Seconds, 300 Seconds, Ether, Tcp/ip Enable, Address, Bootp, Arp/ping, Subnet, Default, Gateway
View all Konica Minolta magicolor 4750EN/4750DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
" If SYS DEFAULT MENU/SECURITY/LOCK PANEL is set to ON, the password must be entered in order for the contents of INTERFACE MEMU to be displayed. For details on LOCK PANEL, refer to "SYS DEFAULT MENU" on page 4-49. " All factory default values are shown in bold. JOB TIMEOUT Settings 5 seconds-15 seconds-300 seconds Specify the timeout interval for a print job being received. ETHER- TCP/IP ENABLE Settings YES/NO NET If YES is selected, TCP/IP is enabled. If NO is selected, TCP/IP is disabled. IP Setting 000.000.000.000 ADDRESS Set the IP address for this printer on the network. Use the , , , and specify the value. keys to If the IP address is manually specified, DHCP, BOOTP and ARP/PING are automatically set to OFF. SUBNET Setting 000.000.000.000 MASK Specify the subnet mask for the network. Use the , , , and specify the value. keys to DEFAULT Setting 000.000.000.000 GATEWAY Specify the IP address of the router if one is on the network. Use the , , DHCP , and keys to specify the value. Settings ON/OFF Select whether or not the IP address is automatically acquired. If ON is selected, the IP address is automatically acquired. If OFF is selected, the IP address is not automatically acquired. 4-44 Configuration Menu Overview