Kyocera TASKalfa 6501i PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013
Kyocera TASKalfa 6501i Manual
View all Kyocera TASKalfa 6501i manuals
Add to My Manuals
Save this manual to your list of manuals |
Kyocera TASKalfa 6501i manual content summary:
- Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 1
PCL Barcode Flash 3.0 User Manual - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 2
KYOCERA Document Solutions Europe B.V. All rights reserved. No part of this manual of service, loss of business KYOCERA Document Solutions Europe B.V. QR Code is a registered trademark of Denso Corporation Maxicode is a registered trademark PDF417 is a registered trademark Microsoft and Windows - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 3
User Manual PCL Barcode Flash Please read this manual before installing and using the software. Keep the manual somewhere close to the printer. 3 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 4
MANUAL 6 1.2 HOW TO USE THIS MANUAL 7 1.3 PURPOSE OF THE APPLICATION 8 1.4 ITEMS PROVIDED AS STANDARD 9 1.5 ABOUT PCL BARCODE FLASH 10 1.5.1 Overview 10 1.5.2 Terminology 10 1.6 THE MAIN FEATURES OF PCL BARCODE FLASH 12 1.7 SUPPORTED 65 3.5 EXAMPLES AND INSTRUCTIONS ON USE 68 3.6 BARCODE - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 5
3.6.7 EAN/JAN-8 + a 5 digit extension 75 3.6.8 EAN/JAN-13 76 3.6.9 EAN/JAN-13 + a 2 digit extension 77 3.6.10 EAN/JAN-13 + a 5 digit extension 78 3.6.11 Interleaved 2 of 5 79 3.6.12 Interleaved 2 of 5 with check digit 80 3.6.13 Industrial 2 of 5 (25 81 3.6.14 Industrial 2 of 5 ( - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 6
on how to install and use the PCL Barcode Flash software for Kyocera printers and multifunction devices. Instructions on the installation and configuration of the devices can be found in the relevant installation and user manuals. You will also find here additional information on programming in - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 7
instructions described are illustrated with examples and - where necessary - printed barcode samples. This manual Kyocera Document Solutions manuals included in the delivery (as a PDF file supported can be found in the chapter entitled SUPPORTED DEVICES. Various fonts are used in this manual - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 8
of the application PCL Barcode Flash enhances Kyocera FS, KM and TASKalfa devices to include additional linear barcodes and PCL activation sequences follow industry-standard formats, there are usually no problems with integrating devices equipped with the Barcode Flash solution into existing - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 9
1.4 Items provided as standard Once you have removed the packaging, please ensure that you have the following components: - a CD containing manual files (in PDF format) and sample prints - a Compact Flash/Secure Digital card (pre-programmed with PCL Barcode Flash software) 9 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 10
PCL Barcode Flash uses a special feature of Kyocera FS, KM and TASKalfa devices: the central unit - consisting of the PowerPC processor, motherboard and in detail in the PRESCRIBE IIe Programming Manual (see appendix). 1.5.2 Terminology In this manual, in most cases we simply refer vertically. 10 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 11
Stack codes essentially consist of up to 90 rather flat linear codes "stacked one on top of the other", so that a data density several times higher can be generated without allowing the dimensions of the codes to become excessively large. Normally, data densities fifteen times higher are achieved - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 12
1D and 2D codes, including QR Code and Datamatrix Compatible with every model in the list of devices supported, no model-dependent versions required PRESCRIBE and PCL commands supported No relevant influence on device speed Demo version without time limit available which can be used to test - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 13
UCC-128 UPC-A UPC-A + 2-character extension UPC-E UPC-E + 2-character extension MSI Plessey MSI Plessey + Mod10 check digit MSI Plessey + Mod10 + Mod10 check digit MSI Plessey + Mod11 + Mod10 check digit ZIP+4 Postnet 5 ZIP+4 Postnet 9 ZIP+4 Postnet 11 Australia 4-State 37-CUST Australia 4-State 52- - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 14
Devices PCL Barcode Flash supports Kyocera printers and multifunction devices. At the time of publishing (version 3.02.17, 03-2013), the following devices are supported: Multifunction Devices (alphabetical order) Model Name Card Type FS-1016MFP - FS-1018MFP - FS-1020MFP - FS-1024MFP - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 15
FS-C1020MFP - FS-C1020MFP+ - FS-C2026MFP B/C FS-C2026MFP+ B/C FS-C2126MFP B/C FS-C2126MFP+ B/C FS-C2526MFP B/C FS-C2626MFP B/C FS-C8020MFP B/C FS-C8025MFP B/C FS-C8520MFP B/C FS-C8525MFP B/C KM-1500 - KM-1620 - KM-1635 - KM-1650 A KM-2020 - KM-2035 - KM-2050 A - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 16
- KM-P4850w - TASKalfa 180 - TASKalfa 181 A TASKalfa 220 - TASKalfa 221 A TASKalfa 250ci B/C TASKalfa 2550ci B/C TASKalfa 300ci B/C TASKalfa 300i B/C TASKalfa 3050ci B/C TASKalfa 3500i B/C TASKalfa 3550ci B/C TASKalfa 400ci B/C TASKalfa 420i B/C TASKalfa 4500i B/C 16 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 17
TASKalfa 4550ci TASKalfa 500ci TASKalfa 520i TASKalfa 5500i TASKalfa 550c TASKalfa 552ci TASKalfa 5550ci TASKalfa 620 TASKalfa 6500i TASKalfa 650c TASKalfa 6550ci TASKalfa 750c TASKalfa 7550ci TASKalfa 8000i TASKalfa 820 Printers (alphabetical order) Model Name FS-1010 FS-1020D FS-1030D FS-1040 FS- - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 18
FS-2000D A FS-2020D B/C FS-2100D/DN D FS-3800 A FS-3820N A FS-3830N A FS-3900DN A FS-3920DN B/C FS-4000DN A FS-4020DN B/C FS-4100DN D FS-4200DN D FS-4300DN D FS-6020 A FS-6950DN A FS-6970DN B/C FS-7000 A FS-820 A FS-9000 A FS-9100DN A FS-9120DN A FS-9130DN - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 19
C8100DN+ A FS-C8500DN A FS-C8600DN B/C FS-C8650DN B/C KM-4800w - TASKalfa 2420w - TASKalfa 4820w - A = B/C = D = - = Compatible with card type / not supported. Solution will not run on these devices. An up-to-date compatibility list is available in the service area of www - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 20
printer environment: - PCL Barcode Flash supports printer control languages PCL and PRESCRIBE these - simultaneously. Therefore, solutions produced by Kyocera development partners, e.g. for data filtering or when the printer is switched on. 1.10 Barcode compatibility PCL Barcode Flash has been - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 21
by copying the right file to the printer. Please observe the instructions in this regard at the beginning of the update file. Please nothe the end user. The KYOmulticode card (PCL Barcode Flash with Unicode font extension and additional fonts) has to be re-programmed by Kyocera customer service if a - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 22
EAN_13mil LetterGothic_10 LetterGothic_12 LetterGothic_17 USPS_ZIP OCR_A OCR_B OCR_B scal Startup ocr_a_9_land ocr_a_10_land ocr_a_9_port ocr_a_10_port ocr_b_12_ext_la ocr_b_12_land ocr_b_12_ext_po ocr_b_12_port Type B/C: /PRE/kmbc3-02-1 /PRE/kmbc3-02-1.inf /PRE/autostart /PRE/bstp /PRE/stp1 /PRE/ - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 23
KMBC3-02-17.so KMBC3-02-17.so.INF autostart BSTP STP1 STP2 STP3 KM_Logo.ttf Let_Got_10 Let_Got_12 Let_Got_17 Linedraw OCR-B_scal OCRA731 OCRA732 OCRA733 OCRA734 OCRB735 OCRB736 OCRB737 OCRB738 OCR_A OCR_B Code39_4 Code39_8 EAN_10mil EAN_13mil USPS_ZIP If required, you can copy additional macro and - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 24
Example of a partition list of Type A: The Device Information contains information on the physical size of the CF/SD card and the memory used. The Partition Information lists print data, macro data and font data which is stored on the card alongside PCL Barcode Flash. This information is technical - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 25
2.2 Activating and deactivating the software (Type A only) Before you can use the software on the CF card in your printer, you have to make this available to the device by activating it. To do this, you have two options: Call the partition Barcode Init via the front panel on your printer, or - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 26
you consult Support, you should always have a current status page to hand. As a rule, the status page helps Support to help you resolve the problem more can be found in the section entitled, Application Information: For service enquiries, the most important details are the Application Version, - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 27
is automatically loaded when the printer is switched on and is immediately available. Therefore, all additional data which you would like to make available to users must be copied into this partition. As a rule, this data includes fonts, macros or print data. 27 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 28
exclusively using the Kyocera language PRESCRIBE. The PCL Barcode Flash software extends the number of barcodes supported to include important new in the Kyocera manual "PRESCRIBE IIE PROGRAMMING MANUAL" (CHAPTER 4: BARCODES), and this is available in both German and English versions (PDF format) - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 29
instructions assume a basic knowledge of PCL programming. If you are not yet confident with using this, we recommend that you read the manuals "font numbers" of the barcodes supported individually. If you would like to (ASCII 13), (ASCII 10), (ASCII 12), (ASCII 27) , - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 30
(ASCII 13),< LF> (ASCII 10), (ASCII 12), (ASCII 27) Any barcode which permits only numeric characters according to the standard is valid as a numeric barcode. Barcodes which also - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 31
in the case of barcode symbols. When a barcode is printed, the cursor moves to the lower right corner of the barcode symbol. See the PCL manual for how to position the cursor. Note In most cases, it is recommended after producing a barcode symbol in PCL that absolute positioning be carried out - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 32
are optional, i.e. you can omit these if your application does not require plain text, for example, or if the width and length in default form are already sufficient for the requirements of your application. Example: (s1p301h20v4b4s24670T instead of just (s24670T v parameter Height of the - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 33
p parameter Positioning of plain text 0 = Use default, cf. the defaults entered for the individual codes for this purpose 1 = no plain text Example: 2 = embedded beneath Example: 3 = half embedded beneath Example: 4 = beneath the barcode - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 34
h parameter Plain text font When you use the h parameter, this always requires a three-digit number, as you can see from the example above. First digit: Font style 1 = regular 2 = italics 3 = bold 4 = bold italics Second digit: Font size 0 = select automatically 1 = use previously selected size for - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 35
T parameter Number of the barcode The number of the required barcode can be taken from the following table: UPC-A UPC-A + 2-digit extension UPC-E UPC-E + 2-digit extension EAN/JAN-8 EAN/JAN-8 + 2-digit extension EAN/JAN-8 + 5-digit extension EAN/JAN-13 EAN/JAN-13 + 2-digit extension EAN/JAN-13 + 5- - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 36
Note If you inadvertently enter a number in the T parameter which does not appear in the preceding table, the printer regards the complete sequence as a font call and not as a barcode call, so any unwanted fonts are activated and the printer attempts to print your base data instead of outputting the - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 37
" (ASCII 34) \ (ASCII 92) # (ASCII 35) { (ASCII 123) $ (ASCII 36) | (ASCII 124) / (ASCII 47) } (ASCII 125) ? (ASCII 63) ~ (ASCII 126) If so required, the Alternative Escape Character mode can be deactivated by means of the PRESCRIBE sequence !R!VBST;E;EXIT; or the Escape - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 38
a range from the 30 symbol numbers, e.g. 10 to 14. In this instance, no symbol smaller than no. 10 will be used, even if the base data unit specified with the command UNIT is used; in this instance, UNIT D being strongly recommended for reasons of accuracy. The information in the case of UNIT does - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 39
, elements such as paper quality and colour, reading distance, scanning technique and light conditions are to be taken into account. When supported. The following 30 Datamatrix symbols are available: Square symbols Symbol no Rows 1 10 2 12 3 14 4 16 5 18 6 20 7 22 8 24 9 26 10 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 40
Rectangular symbols Symbol no . 25 26 27 28 29 30 Rows 8 8 12 12 16 16 Columns 18 32 26 36 36 48 Num. 10 20 32 44 64 98 Data capacity Alphanum. 6 13 22 31 46 72 Binary 3 8 14 20 30 47 Example of a rectangular Datamatrix symbol (symbol no. - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 41
possible to print the symbol completely on the page in the case of very large module sizes. If you do not enter a value, 10 is used as the default. v parameter: inversion 1 = Symbol is not printed inverted 2 = Symbol is printed inverted If you do not enter the v parameter, 1 or not inverted is used - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 42
MANUAL". The BARC command is used. The syntax described in the PRESCRIBE manual for the BARC command is valid for the one-dimensional barcodes supported 100 Module size The unit of module size is preceded by the UNIT command. We recommend that you use dots (pixels) => UNIT D;. Lowest symbol number - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 43
Base Data>EXIT; here is equivalent to exactly 11 bytes (including brackets). Example 2 !R!UNIT D;BARC 100,10,13,14,0,0,"";EXIT; In this case, the bytes do not have to be stated. Example 3 !R!UNIT D;BARC 100,10,10,14,0,0;WRED;EXIT; In this case too, the bytes do not have - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 44
a FONT or MAP command must occur. Example: BARC 120,10,10,14; TEXT „0123456789"; TEXT „0123456789"; The advantage of this mode: As lengthier useful data often have to be printed with Datamatrix, cases may occur in - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 45
3.3.3 QR Code This matrix code was developed by the company Denso and is particularly widespread in Japan, although more recently it has been used within the industry throughout the world. Like the Datamatrix code, the QR Code can also be printed in a variety of sizes and resolutions. QR Code - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 46
read larger symbols can increase dramatically depending on the reading device. You can also select a minimum version or a range of versions, e.g. 10 to 14. No versions lower than 10 will then be used, not even if the base data had also been accommodated in a lower version, and none greater than No - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 47
account paper quality and paper colour, reading distance, scanning technology and lighting conditions, for example. When instruction in a print job to print model 1, it automatically switches to model 2. Extended Channel Interpretation (ECI mode) and Structured Append Mode are not supported - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 48
2 = 15 % 3 = 25 % 4 = 30 % If you do not specify the p parameter, then 15 % is used by default. b parameter: Size of a module in dots relative to 600 dpi Permissible values: 1 - 1000, where it should be noted that a on the page. If you do not specify the b parameter, then 10 is used by default. 48 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 49
not specify the v parameter, then 1 is used by default, i.e. not inverted. Examples: (s4p10h1v12b3s24861TDaten (s12, manual. The command BARC is used. The syntax described in the PRESCRIBE manual for the command BARC applies in respect of the one-dimensional barcodes that are supported - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 50
, which closes the BARC command. The bytes are closed by the WRED command. Example 1 !R!UNIT D;BARC 102,10,13,14,2,4,11;EXIT; here corresponds to exactly 11 bytes. Example 2 !R!UNIT D;BARC 102,10,13,14,2,4,"";EXIT; In this instance it is not necessary to specify the - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 51
!R!UNIT D;BARC 102,10,13 components, weight etc.). In contrast to the other 2D codes supported, the size of the individual modules as well as that of the complete MaxiCode symbol is fixed, i.e. they cannot be modified by the user. The dimensions of the complete symbol are specified as 25.4 mm x - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 52
Syntax in PCL The T-parameter must always be entered. No other parameters are specified with MaxiCode. T-parameter: Identifier for MaxiCode 24800T MaxiCode is initiated by the sequence: (s24800T Additional parameters are not necessary in this sequence; apart from that, the same rules apply as - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 53
is used mainly in applications in the USA and mode 3 is generally used outside of the USA. 4. Postal code 5. Country code 6. Service class Secondary information The secondary information often begins with the character string "[)>"+ RS character (=field separator, ASCII character 30). The individual - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 54
01961Z00004951U SPN06X61015912345671/110YOTT O-HAHN-STRASSE 12MEERBUSCHDE - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 55
1234567 = Shipment 1/1 = Package x of y 10 = Package weight Y = Address validation OTTO-HAHN-STRASSE 12= Ship to address MEERBUSCH= Ship to city DE = Ship to state Syntax in PRESCRIBE To control the - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 56
validity of the country number; the requesting application is exclusively responsible for its accuracy. In modes 4 through 6, the entire entry XBCP 5,# is unnecessary. XBCP 6,#; Service class, which must comply with the specification. The Barcode Flash solution does not verify the validity of the - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 57
06X610159 12345671/110YOTTO-HAHN-STRASSE 12MEERBUSCH - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 58
The level (degree) of error correction can also be selected by the user. Nine levels are available (0-8), whereby level 0 means 'no error correction desired'. Depending on the application and on the quality of the paper used, however, a higher - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 59
Level 0 1 2 3 4 5 6 7 8 Error correction words 2 4 8 16 32 64 128 256 512 Example: (s3p24850T This entry means that you have selected level 3, in other words sixteen error correction words. The barcode module uses this regardless of the size of the useful data. However, you also have - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 60
might overlap. If they overlap as a result of input from the user, the Barcode Flash solution uses the last value entered and selects the one module in dots based on 600 dpi. Standard value is 3; values from 1 to 10 are permissible. 2. X-value for the proportion of the symbol. In the absence of this - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 61
for the proportion of the symbol (cf. sub-parameter 2). 4. Width of a module in 1/100 inch; the standard value is 10. The useful data follow directly after these parameters. Example of a PDF417 request with subsequent font request sequence: (s4,,,15s24850TABCDABCDABCDABCDABCDABCDABCDABCDABC - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 62
Data>, PRESCRIBE number: 46 Activation: !R!BARC 46,C,"Base Data,ABCDE"; EXIT; Example: (s24786T23456789,Info 3. Australia 4-state 67-FF-MET (with 10-character customer information) 62 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 63
PCL T parameter: 24787 Activation: (s24787T PRESCRIBE number: 47 Activation: !R!BARC 47,C,"Base Data,ABCDEFGHIJ"; EXIT; Example: (s24787T23456789,Info 4. Australia 4-state FCC-45 REPLY (reply paid) PCL T parameter: 24788 Activation: (s24788T< - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 64
Please note that no plain text is printed with the Australia 4-state barcode. Note BARC 45, 46, 47 and 48 cannot be called from PRESCRIBE macros. 64 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 65
3.4 Error messages In practice, now and again errors occur when programming barcode activations, particularly during testing of an application. Because the least defective barcodes stand out without the appropriate reading device, error messages are an integrated part of the barcode solution. These - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 66
Target too long The base data was so long that it could not be accommodated by the selected barcode even following optimised compression. Wrong data size You requested QR Code or Datamatrix to use a specific maximum size or a set symbol format. However, they were not able to accommodate the extent - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 67
Codabar. Codabar only allows the letters A,B,C and D as stop characters. Internal error These errors should not really occur. Should any occur, then please contact your Support representative. 67 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 68
instructions on use Do not set the toner density to the lowest contrast value. It is recommended that you set it to a density of 3 or higher. The setting can be made using the control panel or the PRESCRIBE sequence !R! FRPO D4,3;EXIT; The Toner can only be done manually by careful programming and/ - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 69
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 74 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 11 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 70
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 74 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 13 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 71
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 6 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 72
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 8 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 73
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 50 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 7 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 74
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 50 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 9 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 75
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 50 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 12 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 76
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 62 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 12 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 77
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 62 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 14 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 78
3.6.10 EAN/JAN-13 + a 5 digit extension Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 62 p parameter 3 b parameter 8,16,24 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 79
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 2, 4, 6, ... ,98, 100 (even number) Character set: 0 to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 80
Data> For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 1, 3, 5, ... ,97, 99 (odd number) Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 81
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 2, 4, 6, ... ,98, 100 (even number) Character set: 0 to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 82
Data> For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 1, 3, 5, ... ,97, 99 (odd number) Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 83
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 2, 4, 6, ... ,98, 100 (even number) Character set: 0 to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 84
Data> For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 1, 3, 5, ... ,97, 99 (odd number) Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 85
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 Additional properties: Size of base data: 1 to 100 Character set: 0 to 9, A to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 86
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 Additional properties: Size of base data: 1 to 100 Character set: 0 to 9, A to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 87
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 Additional properties: Size of base data: 1 to 100 Character set: 0 to 9, A to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 88
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 Additional properties: Size of base data: 1 to 100 Character set: 0 to 9, A to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 89
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 Additional properties: Size of base data: 1 to 100 Character set: All printable - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 90
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,18 Additional properties: Size of base data: 1 to 100 Character set: All printable - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 91
s24690T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 Additional properties: Size of base data: 1 to 100 Character set: 0 to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 92
s24691T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 Additional properties: Size of base data: 1 to 100 Character set: All - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 93
Base Data> For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 1 to 100 Character set: All printable characters from ASCII - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 94
Base Data> For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 1 to 100 Character set: All printable characters from ASCII - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 95
Base Data> For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 1 to 100 Character set: All printable characters from ASCII - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 96
Data> For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: 1 to 100 Character set: 0 to 9 Example: (s24704T1234567890 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 97
s24710T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 Additional properties: Size of base data: 15 to 21 Character set: 0 to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 98
(s24720T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12,18,24 Additional properties: Size of base data: 1 to 44, maximum size is - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 99
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: Character set: Start and stop characters: 1 to 32 0 to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 100
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: Character set: Start and stop characters: 1 to 32 0 to - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 101
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12 Additional properties: Size of base data: 1 to 14 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 102
For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12 Additional properties: Size of base data: 1 to 14 Character set: 0 to 9 Example - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 103
/ properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code, which means that the h the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 104
/ properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code, which means that the h the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 29 p parameter 1 b parameter 6,12 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 105
: Linear code, used in postal traffic within the U.S.A. Limitation: Plain text is not recommended. This code can only output plain text in the default typeface in a set position below the code. Activation sequence: (s24770T For an explanation on selecting the stop - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 106
: Linear code, used in postal traffic within the U.S.A. Limitation: Plain text is not recommended. This code can only output plain text in the default typeface in a set position below the code. Activation sequence: (s24771T For an explanation on selecting the stop - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 107
: Linear code, used in postal traffic within the U.S.A. Limitation: Plain text is not recommended. This code can only output plain text in the default typeface in a set position below the code. Activation sequence: (s24772T For an explanation on selecting the stop - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 108
3.6.40 Datamatrix Printing examples: The following text is printed out with different parameters as the DataMatrix symbol: 'Data Matrix is a two-dimensional matrix symbology which is made up of square modules arranged within a perimeter finder pattern that is used for finding the symbol and - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 109
SIZE AND INCLINATION. A WIDE RANGE OF SIZES OF SYMBOL IS PROVIDED FOR TOGETHER WITH FOUR LEVELS OF ERROR CORRECTION. MODULE DIMENSIONS ARE USER-SPECIFIED TO ENABLE SYMBOL PRODUCTION BY A WIDE VARIETY OF TECHNIQUES.' ( s5b1p2s24861T ( s11b1p2s24861T - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 110
3.7 Expanding typefaces PCL Barcode Flash expands the integrated default printer typefaces to include Letter Gothic, Line Draw , 'Barcode Font Cartridges' can be controlled using some Microsoft Windows standard printer drivers, and Kyocera devices can now be used for this too. 3.7.1 Checking - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 111
; 12 point: FONT 830; or CSET 0Y; FSET 0p8.1h12v0s0b0T; Barcode 3 of 9; 4.6 cpi; 12 point: FONT 831; or CSET 0Y; FSET 0p4.6h12v0s0b0T; EAN/UPC 10 Mil; proportional; 12 point: FONT 832; or CSET 8Y; FSET 1p12v0s0b0T; EAN/UPC 13 Mil; proportional; 12 point: FONT 833; or CSET 8Y; FSET 1p12v0s3b0T - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 112
a PCL command In the PCL emulation of Kyocera devices, the fonts can also be selected using 13 Mil; prop.; Letter Gothic; 17 cpi; Letter Gothic; 12 cpi; Letter Gothic; 10 cpi; Line Draw; 10 cpi; OCR-A; 10 cpi; OCR-B; 10 cpi; USPS ZIP; prop.; 12 point: 12 point: 12 point: 12 point: 9.5 - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 113
3.7.4 Examples Print out a barcode 39 with PRESCRIBE: !R! FONT 831; TEXT "*0987654321*"; PAGE; EXIT; ("*" required as the start and stop character) Print out of a UPC barcode with ORC-A script embedded below in PCL: [cr][lf] [esc](8Y[esc](s1p12v0s0b0T(012345-GHIJAF([cr][lf] (012345-GHIJAF([cr][ - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 114
can be purchased from www.iso.ch It is generally recommended that you familiarise yourself with the following official manuals, which are normally included on CD as a PDF document with every Kyocera device: - PRESCRIBE IIe Programming Manual (English) - PDF417 Two Dimensional Bar Code Implementation - Kyocera TASKalfa 6501i | PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 115
115 3.2 EN (03/2013)
PCL Barcode Flash 3.0
User Manual