3.6 Barcode Types 3.6.1 UPC-A Type / properties: Linear code Limitation: Plain text is only output in the default typeface in a set position below the code. Activation sequence: (s24600T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter 74 p parameter 3 b parameter 8,16,24,32 Additional properties: Size of base data: 11 Character set: 0 to 9 Example: (s24600T01234567890 69
69
3.6 Barcode Types
3.6.1 UPC-A
Type / properties:
Linear code
Limitation: Plain text is only output in the default typeface in a set position below the
code.
Activation sequence:
<Esc>(s24600T<Base Data><Stop Character>
For an explanation on selecting the stop character and the optional parameters, see
chapters 3.2.1. and 3.2.6.
Default - parameters:
v parameter
74
p parameter
3
b parameter
8,16,24,32
Additional properties:
Size of base data:
11
Character set:
0 to 9
Example:
<Esc>(s24600T01234567890<CR>