Kyocera TASKalfa 6501i PCL Barcode Flash 3.0 User's Manual Rev 3.2.03.2013 - Page 99
Codabar
View all Kyocera TASKalfa 6501i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
3.6.31 Codabar Type / properties: Linear code Activation sequence: (s24750T For an explanation on selecting the stop character and the optional parameters, see chapters 3.2.1. and 3.2.6. Default - parameters: v parameter p parameter b parameter Additional properties: Size of base data: Character set: Start and stop characters: 1 to 32 0 to 9 A B C D Example: (s24750TA1234567890B 99
99
3.6.31 Codabar
Type / properties:
Linear code
Activation sequence:
<Esc>(s24750T<Base Data><Stop Character>
For an explanation on selecting the stop character and the optional parameters, see
chapters 3.2.1. and 3.2.6.
Default - parameters:
v parameter
p parameter
b parameter
Additional properties:
Size of base data:
1 to 32
Character set:
0 to 9, $ + - . / :
Start and stop characters:
A B C D
Example:
<Esc>(s24750TA1234567890B<CR>