LG 26LH1DC4 Owners Manual - Page 115
Abnormal State Command 2 : z, ISM Method, Command 1 : j, Low Power, Real data mapping 1, Transmission
View all LG 26LH1DC4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 115 highlights
19. Abnormal State (Command 2 : z) G To recognize an abnormal state. Transmission [k][z][ ][Set ID][ ][FF][ ][Cr] Data FF : Read Ack [z][ ][Set ID][ ][OK][Data][x] Data 0: Normal (Power on and signal exist) 1: No signal (Power on) 2: Turn the monitor off by remote control 3: Turn the monitor off by sleep time function 4: Turn the monitor off by RS-232C function 5: 5V down 6: AC down 7: Turn the monitor off by Fan Alarm function 8: Turn the monitor off by Off time function 9: Turn the monitor off by Auto sleep function * This function is "read only". 20. ISM Method (Command 1 : j, Command 2 : p) G To control the ISM method. You can also adjust ISM Method in OPTION menu. It's not available to use this function in LCD TV models. Transmission [j][p][ ][Set ID][ ][Data][Cr] Data 0: Normal 1: White wash 2: Orbiter 3: Inversion Ack [p][ ][Set ID][ ][OK/NG][Data][x] 21. Low Power (Command 1 : j, Command 2 : q) G To reduce the power consumption of the set. You can also adjust Low Power in OPTION menu. It's not available to use this function in LCD TV models. Transmission [j][q][ ][Set ID][ ][Data][ ][Cr] Data 0 : Off 1 : On Ack [q][ ][Set ID][ ][OK/NG][Data][x] APPENDIX * Real data mapping 1 0 : Step 0 A : Step 10 (Set ID 10) F : Step 15 (Set ID 15) 10 : Step 16 (Set ID 16) 64 : Step 100 6E : Step 110 73 : Step 115 74 : Step 116 C7: Step 199 FE : Step 254 FF : Step 255 * Real data mapping 2 0 : -40 1 : -39 2 : -38 28 :0 4E : +38 4F : +39 50 : +40 113