ENGLISH WARNING •• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary. •• The power supply cord and plug should not be modified. If it will not fit the outlet, have a proper outlet Installed by a qualified electrician. •• Using an extension cord to connect the power is prohibited. Connect the power cord and plug directly. •• Electrical ground is required on this appliance. •• Make sure that the power cord is not pinched by the range or heavy objects. Failure to do so can result in serious burns or electrical shock. Specified power-supply-cord kit rating Range rating, watts 120/240 volts 3-wire 120/208 volts 3-wire Specified rating of power supplycord kit, amperes Diameter (inches) of Range connection Opening Power cord Conduit 8,750 - 7,801 - 40 or 50A 1 3/8" 16,500 12,500 1 1/8" 16,501 - 12,501 - 50 22,500 18,500 1 3/4" 1 3/8" 3, 4 - Wire electrical wall Receptacle 4 Wire receptacle (14-50R) 3 Wire receptacle (10-50R) Connecting the Power Cord The rear access cover must be removed. Loosen the two screws with a screwdriver. The terminal block will then be accessible. INSTALLATION 15 Use the cord/conduit connection plate to install the power cord or conduit. Leave the connection plate as installed for power cord installations. Remove the connection plate for conduit installations and use the smaller 11/8 in. (2.8 cm) conduit hole instead of the 13/8 in. (3.5 cm) power cord hole. 11/8" (2.8 cm) Conduit 13/8" (3.5 cm) Cord Remove the Conduit connection plate For power cord installations, hook the strain relief over the 13/8 in. (3.5 cm) power cord hole located below the rear of the oven. Insert the power cord through the strain relief and tighten it. Conduit connection plate Power cord Assembling power cord strain relief at the 13/8" opening For conduit installations, insert the conduit strain relief in the 11/8 in. (2.8 cm) conduit hole. Then install the conduit through the body of the strain relief and fasten the strain relief with its ring. Ring Cord/ Conduit connection plate Body Conduit Assembling conduit cord strain relief at the 11/8" opening Access cover

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

15
INSTALLATION
ENGLISH
WARNING
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack
in the line so that the range can be moved if
servicing is ever necessary.
The power supply cord and plug should
not be modified. If it will not fit the outlet,
have a proper outlet Installed by a qualified
electrician.
Using an extension cord to connect the
power is prohibited. Connect the power
cord and plug directly.
Electrical ground is required on this
appliance.
Make sure that the power cord is not
pinched by the range or heavy objects.
Failure to do so can result in serious burns or
electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
Specified
rating of
power
supply-
cord kit,
amperes
Diameter (inches)
of Range
connection
Opening
120/240
volts
3-wire
120/208
volts
3-wire
Power
cord
Conduit
8,750 -
16,500
16,501 -
22,500
7,801 -
12,500
12,501 -
18,500
40 or 50A
50
1
3
/
8
"
1
3
/
4
"
1
1
/
8
"
1
3
/
8
"
3, 4 - Wire electrical wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
Connecting the Power Cord
The rear access cover must be removed. Loosen the
two screws with a screwdriver. The terminal block will
then be accessible.
Access cover
Use the cord/conduit connection plate to install the
power cord or conduit. Leave the connection plate
as installed for power cord installations. Remove the
connection plate for conduit installations and use the
smaller 1
1
/
8
in. (2.8 cm) conduit hole instead of the
1
3
/
8
in. (3.5 cm) power cord hole.
Remove the Conduit connection plate
1
1
/
8
"
(2.8 cm) Conduit
1
3
/
8
"
(3.5 cm) Cord
For power cord installations, hook the strain relief
over the 1
3
/
8
in. (3.5 cm) power cord hole located
below the rear of the oven. Insert the power cord
through the strain relief and tighten it.
Conduit
connection
plate
Power cord
Assembling power cord strain relief at the 1
3
/
8
" opening
For conduit installations, insert the conduit strain
relief in the 1
1
/
8
in. (2.8 cm) conduit hole. Then install
the conduit through the body of the strain relief and
fasten the strain relief with its ring.
Cord/
Conduit
connection
plate
Conduit
Ring
Body
Assembling conduit cord strain relief at the 1