LG M6100 Service Manual - Page 61
Table 4-2
View all LG M6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
4. TROUBLE SHOOTING Checking Flow For these 2 test case, No Call connection is needed Check SW500 Pin ANT,RF with RF Cable connected. Check SW601 Pin ANT,RF with No RF Cable Connected Check C505,C506,C507 Check whether FEM Set as RX mode Refer to Table 4-2 Open No Yes Short No Yes VC1 :Low or HIGH No VC2 :Low VC3:LOW Yes Changing SW501 Changing SW501 Changing the Board. Check RF Level of FL501.6 (for GSM) & FL501.4 Pin6 : ~ -62dBm No (for DCS) & FL501.2 (for PCS) Pin 4,2 : ~ -63dBm Yes FEM & Mobile SW is OK See next Page to check Rx IQ Signal For this RF Level test case, RX Stand alone Mode is needed Changing FL501 EGSM-Tx EGSM-Rx DCS/PCS-Tx DCS-Rx PCS-Rx Vc1 0.0-0.1V 0.0-0.1V 0.0-0.1V 0.0-0.1V 2.3-3.0V Vc2 0.0-0.1V 0.0-0.1V 2.3-3.0V 0.0-0.1V 0.0-0.1V Table 4-2 Vc3 2.3-3.0V 0.0-0.1V 0.0-0.1V 0.0-0.1V 0.0-0.1V Current 10mA Max ≈ 0mA 10mA Max ≈ 0mA 10mA Max - 62 -