Panasonic KXTA30820 Installation Manual - Page 215
[101] Station Hunting Type
UPC - 037988850709
View all Panasonic KXTA30820 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 215 highlights
4.2 System Programming 101 Station Hunting Type Description Selection Default Programming Conditions Feature Reference Used to set the Station Hunting type for each extension group. There are two Station Hunting types available: Circular and Terminating. If circular is assigned for a group, all of the extensions in the group are searched one time until an idle one is found. If terminating is assigned, searching stops at the extension which has the highest jack number in the group. • Extension group number: 1 - 8, ( = all extension groups) • Terminate (terminating) / Circular All extension groups - Terminate 1. Enter 101. Display: Hunting Type 2. Press NEXT. Display: Group NO? → 3. Enter an extension group number. Pressing NEXT also can enter extension group number 1. Display example: Group1:Terminate 4. Keep pressing SELECT until the desired selection is displayed. 5. Press STORE. 6. To program another extension group, press NEXT or PREV, or SELECT and enter the desired extension group number. 7. Repeat steps 4 through 6. 8. Press END. • Program [600] "Extension Group Assignment" is used to assign the extension group members. • If all extensions are busy, a busy tone will be heard. Section 3, Features Station Hunting System Programming 4-23