Panasonic SDC615 AJSDC615 User Guide - Page 82
Rec Function
UPC - 791871302699
View all Panasonic SDC615 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Chapter 7 Menu description tables 7-2-3 REC FUNCTION Item/ Data storage Variable range Remarks INTERVAL REC MODE F ON ONE SHOT OFF For setting the INTERVAL REC function. ON (MEMORY): Interval recording is possible in singleframe units using memory. ONE SHOT: Recording is performed only once for the time set in the REC TIME item, after which it stops. OFF: Interval recording is not performed. REC TIME SDC905 CUF 00s01f : 59s29f For setting the recording time (one cut). The shortest time is one frame. SDC615 CUF 02s00f : 59s29f The shortest time is two seconds. PAUSE TIME SDC905 CUF 00h00m00s01f : 00h04m59s29f : 23h59m59s29f For setting the recording pause time. The shortest time is one frame. SDC615 CUF 00h00m02s00f : 00h04m59s29f : 23h59m59s29f The shortest time is two seconds. TAKE TOTAL TIME CUF NONE : 5day For setting the time required for shooting. Select a setting from NONE (shooting continues until it is stopped manually) to 5DAY (5 days). TOTAL REC TIME 00m00s01f : 90m59s29f OVER 100min NONE For displaying the total recording time. The setting for this time cannot be changed. The total time yielded by adding the REC TIME, PAUSE TIME and TOTAL TAKE TIME is displayed. AUDIO REC OFF C U F ON For setting whether or not to record the sound. START DELAY CUF 0SEC : 10SEC For setting the time taken until recording is to start after the REC START button is pressed in the INTERVAL REC mode. PRE REC MODE SDC905 OFF 0SEC : 6SEC CUF For setting the PRE REC function. OFF: The PRE REC function is not operable. 0-6SEC: The duration for which pre- recording can be performed after the REC START button is pressed is set here. NEWS REC MODE SDC615 CUF OFF 0.2SEC : 2.0SEC For setting the NEWS REC time. RETAKE MODE ON OFF F For selecting whether or not to allow retake operations (MODE CHECK switch + RET switch). The REC TIME, PAUSE TIME and TOTAL REC TIME values are given in terms of the drop frames during drop frame operations and in terms of non-drop frames during non-drop frame operations. The TAKE TOTAL TIME value is the actual time. This means that a fraction may apply to the TOTAL REC TIME depending on the setting used. Example in the case of drop frame operation REC TIME PAUSE TIME 02s00f 02s00f TAKE TOTAL TIME TOTAL REC TIME 40min 19m59s06f The underlining in the variable range column indicates the setting in the preset mode. 82