Schwinn 490 Elliptical Service Manual - Page 21
The Console display shows the AUTO CAL_RESIS
View all Schwinn 490 Elliptical manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
6. The Console display shows the AUTO CAL_RESISTANCE (Automated Calibrate Resistance) option. Push the Start button. Note: If the Pause/Stop button is pushed part way through the calibration (exit), the new calibration is not saved. 7. The console will display changing text and numbers for approximately 30 seconds as the servo motor moves. 8. The console display will change to "CNFRM C4095 AGC xx". 9. Push the Start button to confirm and save the resistance calibration values. The display will momentarily change to "SAVING CAL", then display "AUTO CAL_RESISTANCE". Calibration is complete. Note: Pushing the Pause/Stop button will abort the calibration process, with the new calibration values not being saved, and the last saved calibration values being restored. 10. Power off the machine. 11. Power on the machine. After the Power-Up/Welcome screen appears, use the Resistance Level Quick keys 25 and 1 to confirm that the magnet caliper moves properly between resistance level 1 and 25. 12. Final Inspection Inspect your machine to ensure that all hardware is tight and components are properly assembled. Do not use until the machine has been fully assembled and inspected for correct performance in accordance with the Owner's Manual. 21